Remove Power
Remove Power
Use this procedure to completely remove power from the server. Changing the server from
Main power mode to Standby power mode does
not
completely remove power from the server.
If you need to completely remove power from the server to perform cold service or a cold reset
or to place the server in a non-powered state, you must disconnect the AC power cables from
the back of the server.
Before You Begin
See:
“Power Control, Shutdown, and Reset States” on page 118
1.
Place the server in Standby power mode.
Use one of the power off methods. See
“Powering Down the Server” on page 111
2.
Access the back of the server.
3.
To remove power from the server, lift the power cord retaining clips, and
disconnect each AC power cable from the AC power block.
This action completely removes power from the server.
4.
If you are performing a cold reset, wait at least 60 seconds before connecting the
AC power cables to the power supplies.
For information about cold resets, see
“Power Control, Shutdown, and Reset
.
Preparing for Service
119