Power On the Server
Returning the Server to Operation
237
1.
Release the slide rails from the fully extended position by pushing the release
tabs on the side of each rail.
2.
While pushing on the release tabs, slowly push the server into the rack.
Ensure that the cables do not get in the way.
3.
Reconnect the cables to the back of the server.
If the cable management arm (CMA) is in the way, disconnect the left CMA release and swing
the CMA open.
4.
Reconnect the CMA.
Swing the CMA closed and latch it to the left rack rail.
Power On the Server
If you removed power from the server during maintenance, use the following procedure to
reapply main power for all server components.
1.
Verify that the power cords are connected to the server and that standby power
is on.