Hot Plugging of Some PCIe ExpressModules Not Supported by Windows Server 2008 R2 (CR 6914898, CR 6793369, CR
6923132)
1. Ignore these false processor faults when they're associated with a uncorrectable DIMM
reset.
2. Handle the DIMM errors like you would any other DIMM error, and clear the DIMM faults.
3. Clear the processor faults.
4. Power-cycle the server.
For example, in the Oracle ILOM Remote Power Control tab, select Power Cycle or
Immediate Power Off.
Note -
Resetting the server without toggling the power (for example, by issuing a
reset
command) does not clear the CPU error.
Hot Plugging of Some PCIe ExpressModules Not Supported
by Windows Server 2008 R2 (CR 6914898, CR 6793369, CR
6923132)
Windows Server 2008 R2 does not support hot plugging on certain PCIe ExpressModules.
These include:
■
SG-XPCIE2FCGBE-Q-Z - Sun StorageTek Dual FC Dual GbE HBA Express Module
■
SG-XPCIE2FCGBE-E-Z - Sun StorageTek Dual FC Dual GbE HBA Express Module
■
SG-XPCIEFCGBE-Q8-Z - Sun StorageTek Dual 8GB FC Dual GbE HBA Express Module
■
SG-XPCIEFCGBE-E8-Z - Sun StorageTek Dual 8GB FC Dual GbE HBA Express Module
■
X7284A-Z - Sun Quad GbE ExpressModule
Workaround
Reboot the system after changing one of these PCIe ExpressModules.
PXE Installation of Windows Server 2008 R2 Fails at
Authentication (CR 6899582)
During a PXE installation of Windows Server 2008 R2, if PXE user authentication fails, check
that the system date and time are set correctly. If the systems date and time is incorrect, PXE
authentication fails, and the network installation of Windows Server 2008 R2 does not happen.
64
Sun Fire X4800 Server Product Notes • July 2017
Содержание Sun Fire X4800
Страница 1: ...Sun Fire X4800 Server Product Notes Part No E69641 07 July 2017 ...
Страница 2: ......
Страница 12: ...12 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 26: ...26 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 60: ...60 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 88: ...88 Sun Fire X4800 Server Product Notes July 2017 ...