Message About Missing Disks After Failed Boot (CR 6939507)
Message About Missing Disks After Failed Boot (CR
6939507)
On rare occasions, after initial power up, the system fails to boot and displays a message:
All of the disks from your previous configuration are gone.
If this is an unexpected message, then please power off your system and check
your cables to ensure all disks are present. Press any key to continue, or "C"
to load the configuration utility.
Workaround
1. Power cycle the system.
The system should boot normally.
2. If the system still does not boot, and the same message appears, contact Oracle customer
service.
System Does Not Power Up After Power Cycling (CR
6950414)
Under rare conditions, when the system is power-cycled, it might not power up.
Workaround
Remove and reapply AC power to and from the system.
Either:
■
Switch the AC power Off then switch it back On.
■
Remove all the AC power cords from the power supplies and then plug them back in.
■
Remove the power supplies and then replace them.
System Does Not Recognize DIMM Due to SPD Corruption
(CR 6946921)
Under rare conditions, a DIMM can get corrupted. When this happens, the system no longer
recognizes that DIMM, and as a result, the system has less memory available to it than what
was configured.
Hardware Issues
41
Содержание Sun Fire X4800
Страница 1: ...Sun Fire X4800 Server Product Notes Part No E69641 07 July 2017 ...
Страница 2: ......
Страница 12: ...12 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 26: ...26 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 60: ...60 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 88: ...88 Sun Fire X4800 Server Product Notes July 2017 ...