Installing the Switch
107
■
“Identify the CMC Addresses” on page 87
■
“Identify the Fabric Card Addresses” on page 99
■
“Identify the CXP Connector Addresses” on page 117
▼
Display the Line Card FRU ID Information
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
2. On the CMC, type:
where
IPMB_address
is from
“Identify the Line Card Addresses” on page 106
.
The following example is the output for line card 8:
3. Repeat
for all installed line cards.
#
clia fruinfo
IPMB_address
0
#
clia fruinfo 92 0
Pigeon Point Shelf Manager Command Line Interpreter
92: FRU # 0, FRU Info
Common Header: Format Version = 1
Board Info Area:
Version = 1
Language Code = 25
Mfg Date/Time = Mar 31 16:22:00 2009 (6967702 minutes since 1996)
Board Manufacturer = Sun Microsystems, Inc.
Board Product Name = Sun Datacenter Switch DCS 648 - Line Card
Board Serial Number = 54138100911LC0046
Board Part Number = 541-3810-02
FRU Programmer File ID = m9_lc_fru-info-54138100911LC0046.inf
Product Info Area:
Version = 1
Language Code = 25
Manufacturer Name = Sun Microsystems, Inc.
Product Name = Sun Datacenter Switch DCS 648 - Line Card
Product Part / Model# = 541-3810-02
Product Version = Rev 2
Product Serial Number = 54138100911LC0046
Asset Tag = none
FRU Programmer File ID = m9_lc_fru-info-54138100911LC0046.inf
#
Содержание Sun Datacenter InfiniBand Switch 648
Страница 1: ...Sun Datacenter InfiniBand Switch 648 Installation Guide Part No 820 7738 12 May 2010 Revision A ...
Страница 8: ...viii Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 134: ...124 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 140: ...130 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...