Verify the Battery
timezone = EDT (EST5EDT)
uptime = 2 days 19:56:49
usentpserver = disabled
b.
If the SP policy
HOST_AUTO_POWER_ON
was enabled before you replaced the
battery, you must re-enable it.
->
set /SP/policy HOST_AUTO_POWER_ON=enabled
c.
If the
/SP/clock
usentpserver
property was enabled before you replaced the
battery, you must re-enable it.
->
set /SP/clock usentpserver=enabled
4.
Related Information
■
“Detecting and Managing Faults” on page 25
Verify the Battery
1.
Run
show
/SYS/MB/V_BAT
to check the status of the system battery.
In the output, the
/SYS/MB/BAT
status should be
OK
, as in the following example.
->
show /SYS/MB/BAT
Targets:
Properties:
type = Battery
ipmi_name = MB/BAT
class = Threshold Sensor
value = 3.140 Volts
upper_nonrecov_threshold = N/A
upper_critical_threshold = N/A
upper_noncritical_threshold = N/A
lower_noncritical_threshold = 2.704 Volts
lower_critical_threshold = N/A
lower_nonrecov_threshold = N/A
alarm_status = cleared
Commands:
cd
show
2.
Verify that the value in the
value
column shows a voltage of 2.8V or more.
132
SPARC T8-4 Server Service Manual • January 2022
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...