Remove a DIMM
3.
Verify that the Memory Riser Power LED next to the button is illuminated.
An illuminated Memory Riser Power LED indicates that there is power available to illuminate
any Memory DIMM Fault LEDs once you have pressed the DIMM Fault Remind button.
4.
Press the DIMM Fault Remind button on the processor module.
This will cause the Memory DIMM Fault LEDs associated with any faulty DIMMs to
illuminate for a few minutes.
5.
Note the address of the DIMM next to any illuminated Memory DIMM Fault LED.
6.
Ensure that all other DIMMs are seated correctly in their slots.
Related Information
■
“Determine Which DIMM Is Faulty (Oracle ILOM)” on page 75
■
“Determine Which DIMM Is Faulty (PSH)” on page 75
Remove a DIMM
DIMMs are cold-service components that can be replaced by customers. For the location of the
DIMMs, see
“Processor Module Components” on page 19
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
1.
Consider your first steps.
■
Familiarize yourself with DIMM population rules.
See
“Understanding DIMM Configurations” on page 69
■
Prepare the system for service.
See
“Preparing for Service” on page 43
■
Remove the processor module. Place the processor module on an ESD-
protect work surface.
See
“Remove a Processor Module or Processor Filler Module” on page 60
.
2.
Remove the cover from the processor module.
78
SPARC T7-4 Server Service Manual • May 2017
Содержание SPARC T7-4
Страница 1: ...SPARC T7 4 Server Service Manual Part No E54994 07 May 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC T7 4 Server Service Manual May 2017 ...
Страница 12: ...12 SPARC T7 4 Server Service Manual May 2017 ...
Страница 86: ...86 SPARC T7 4 Server Service Manual May 2017 ...
Страница 98: ...98 SPARC T7 4 Server Service Manual May 2017 ...
Страница 110: ...110 SPARC T7 4 Server Service Manual May 2017 ...
Страница 124: ...124 SPARC T7 4 Server Service Manual May 2017 ...
Страница 141: ...Verify the Battery Related Information Replace the Battery on page 137 Servicing the Battery 141 ...
Страница 142: ...142 SPARC T7 4 Server Service Manual May 2017 ...
Страница 164: ...164 SPARC T7 4 Server Service Manual May 2017 ...
Страница 175: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 175 ...
Страница 192: ...192 SPARC T7 4 Server Service Manual May 2017 ...
Страница 200: ...200 SPARC T7 4 Server Service Manual May 2017 ...
Страница 208: ...208 SPARC T7 4 Server Service Manual May 2017 ...