Verify a Fan Module
Verify a Fan Module
1.
Verify that the Service Required LED on the replaced fan module is not lit.
2.
At the Oracle ILOM prompt, start the fault management shell.
->
start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)?
y
faultmgmtsp>
3.
Type
fmadm faulty
to check for faults.
■
If faults are reported, see
“Detecting and Managing Faults” on page 29
■
If no faults are reported, then the component has been replaced successfully.
4.
Consider these possibilities:
■
If any of the LEDs are illuminated, see
“Interpreting LEDs” on page 35
■
If none of the LEDs are illuminated, the fan module has been replaced successfully.
Related Information
■
“Determine Which Fan Module Is Faulty” on page 79
■
“Front Panel Components (Service)” on page 13
■
“Rear Panel Components (Service)” on page 15
Servicing Fan Modules
83
Содержание SPARC T7-2
Страница 1: ...SPARC T7 2 Server Service Manual Part No E54987 10 July 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T7 2 Server Service Manual July 2019 ...
Страница 12: ...12 SPARC T7 2 Server Service Manual July 2019 ...
Страница 28: ...28 SPARC T7 2 Server Service Manual July 2019 ...
Страница 64: ...64 SPARC T7 2 Server Service Manual July 2019 ...
Страница 84: ...84 SPARC T7 2 Server Service Manual July 2019 ...
Страница 112: ...112 SPARC T7 2 Server Service Manual July 2019 ...
Страница 116: ...116 SPARC T7 2 Server Service Manual July 2019 ...
Страница 120: ...120 SPARC T7 2 Server Service Manual July 2019 ...
Страница 134: ...134 SPARC T7 2 Server Service Manual July 2019 ...
Страница 146: ...146 SPARC T7 2 Server Service Manual July 2019 ...
Страница 164: ...164 SPARC T7 2 Server Service Manual July 2019 ...
Страница 170: ...170 SPARC T7 2 Server Service Manual July 2019 ...
Страница 176: ...176 SPARC T7 2 Server Service Manual July 2019 ...
Страница 182: ...182 SPARC T7 2 Server Service Manual July 2019 ...
Страница 188: ...188 SPARC T7 2 Server Service Manual July 2019 ...