Check the Power State of the Server or Host (Oracle ILOM)
Check the Power State of the Server or Host (Oracle
ILOM)
1.
Log in to Oracle ILOM.
“Log In to Oracle ILOM (Service)” on page 67
.
2.
Determine if the system or domain has power.
■
To check the power status of a domain on a single-domain server, at the Oracle ILOM
prompt, type:
->
show /System power_state
■
To show the power state for a specific domain, at the Oracle ILOM prompt, type:
->
show /Servers/PDomains/PDomain_
x
/HOST power_state
3.
Determine your next step.
■
If the system or domain is running (
power_state=on
), and you want to remove power, see
“Removing Power From the Server or Domain” on page 69
.
■
If the system or domain is not running (
power_state=off
), and you want to power it on, see
“Returning the Server to Operation” on page 73
.
Related Information
■
http://www.oracle.com/goto/ilom/docs
)
■
“Log In to Oracle ILOM (Service)” on page 67
■
“Removing Power From the Server or Domain” on page 69
■
“Returning the Server to Operation” on page 73
Return a Component to Service
If you unseat a component but do not remove it from the server, or if you use the
prepare_to_remove
command for a component but decide not to remove it, you must return the
component to service before it can be made operational.
Return the component to service.
->
cd /System/
target-name
->
set action=return_to_service
Controlling the Server and Domains
75
Содержание SPARC M7
Страница 1: ...SPARC M8 and SPARC M7 Servers Service Manual Part No E55215 06 September 2017 ...
Страница 2: ......
Страница 12: ...12 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 14: ...14 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 34: ...34 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 66: ...66 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 78: ...78 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 116: ...116 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 140: ...140 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 187: ...Install a Fan Module Switch Chassis Switch Chassis Cooling Zones on page 31 Servicing Fan Modules Switch Chassis 187 ...
Страница 188: ...188 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 216: ...216 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 226: ...226 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 234: ...234 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 242: ...242 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 252: ...252 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 268: ...268 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 296: ...296 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 316: ...316 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...