Servicing the Front Indicator Panel Cable
The front indicator panel cable connects the front indicator panel to the chassis.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail. Follow antistatic precautions to
prevent electrostatic damage. See
“Prevent ESD Damage” on page 61
These topics explain how to service the front indicator panel cable.
■
“Remove the Front Indicator Panel Cable” on page 227
■
“Install the Front Indicator Panel Cable” on page 232
Related Information
■
“Identifying Components” on page 15
■
“Detecting and Managing Faults” on page 35
■
“Preparing for Service” on page 57
■
“Controlling the Server and Domains” on page 67
■
“Understanding Server Configurations and Failover Behavior” on page 79
Remove the Front Indicator Panel Cable
This procedure can be performed only by qualified service personnel.
Caution -
Remove AC power using the circuit breakers on the appropriate PDU before
performing this procedure.
1.
Determine which front indicator panel cable requires service.
“Identify Faulted Components” on page 36
Servicing the Front Indicator Panel Cable
227
Содержание SPARC M7
Страница 1: ...SPARC M8 and SPARC M7 Servers Service Manual Part No E55215 06 September 2017 ...
Страница 2: ......
Страница 12: ...12 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 14: ...14 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 34: ...34 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 66: ...66 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 78: ...78 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 116: ...116 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 140: ...140 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 187: ...Install a Fan Module Switch Chassis Switch Chassis Cooling Zones on page 31 Servicing Fan Modules Switch Chassis 187 ...
Страница 188: ...188 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 216: ...216 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 226: ...226 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 234: ...234 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 242: ...242 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 252: ...252 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 268: ...268 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 296: ...296 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Страница 316: ...316 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...