Utility-Related Issues
■
“Cannot Delete a RAID Volume Using the
■
Utility Command for Creating a RAID 10 Volume” on page 64
Sun Storage 6 Gb SAS PCIe HBA, Internal is Not
Displayed in the BIOS Setup Utility
Bug 15803027
Issue:
If you have a Sun Storage 6 Gb SAS PCIe HBA, Internal and a Sun Storage 6 Gb SAS
PCIe HBA, External installed in a Sun Server X2-4 system, the Sun Storage 6 Gb SAS PCIe
HBA, Internal might not be displayed in the BIOS Setup utility.
Workaround:
The Sun Storage 6 Gb SAS PCIe HBA, Internal and Sun Storage 6 Gb SAS
PCIe HBA, External must have the same level of firmware installed. If you encounter this issue,
upgrade the firmware on the HBAs to be the latest firmware version. You can now see both
HBAs in the BIOS Setup utility.
A Hard Drive is Not Displayed in the BIOS Setup
Utility
Bug 15769403
Issue:
After removing and reinserting a hard drive that is part of a RAID-1 virtual drive
configuration on the HBA, the hard drive is no longer displayed in the BIOS Setup utility.
Workaround:
None. This is expected behaviour. To view the hard drive after reinsertion,
reboot the system and enter the BIOS Setup utility. You can now view the hard drive.
Non-Alphabetical Characters Are Displayed in
RAID Volume Names
Bug 15597943
Issue:
In the LSI BIOS Configuration utility, non-alphabetical characters are occasionally
displayed in the volume names of RAID volumes. This occurs intermittently; subsequent
reboots might cause the characters to go away, resulting in the correct volume names being
displayed, or might cause the garbled characters to continue to be displayed. This is a cosmetic
issue only. The volumes are fully functional and usable.
Chapter 6 • Known Issues
63
Содержание SG-SAS6-INT-Z
Страница 2: ......