Restore the Host Power State at Restart
■
enabled
– Server cools certain components before powering off.
■
disabled
– Component temperatures are not monitored during power off.
Related Information
■
“Power Off the Server (Oracle ILOM Web Interface)” on page 26
■
“Power Off the Server (Oracle ILOM CLI)” on page 24
Restore the Host Power State at Restart
Use the
/SP/policy HOST_LAST_POWER_STATE
property to control the behavior of the server
after an unexpected power outage. When external power is restored, the Oracle ILOM SP starts
to run automatically. Normally, the host power is not turned on until you use Oracle ILOM to
turn it on.
Oracle ILOM records the current power state of the server in nonvolatile storage. If the
HOST_LAST_POWER_STATE
policy is enabled, Oracle ILOM can restore the host to the previous
power state. This policy is useful in the event of a power failure, or if you physically move the
server to a different location.
For example, if the host server is running when power is lost and the
/SP/policy
HOST_LAST_POWER_STATE
property is set to
disabled
, the host server remains off when power is
restored. If the
/SP/policy HOST_LAST_POWER_STATE
property is set to
enabled
, the host server
restarts when the power is restored.
At the Oracle ILOM prompt, type:
->
set /SP/policy HOST_LAST_POWER_STATE=enabled
where
value
can be:
■
enabled
– When power is restored, returns the server to the state it was in before the power
was removed.
■
disabled
– (Default) Keeps the server off when power is applied.
If you enable
HOST_LAST_POWER_STATE
, you should also configure
/SP/policy
HOST_POWER_ON_DELAY
“Disable or Reenable the Host Power-On Delay” on page 59
Related Information
■
“Disable or Reenable the Host Power-On Delay” on page 59
58
SPARC and Netra SPARC T5 Series Servers Administration Guide • August 2016
Содержание Netra SPARC
Страница 1: ...SPARC and Netra SPARC T5 Series Servers Administration Guide Part No E29502 10 August 2016 ...
Страница 2: ......
Страница 10: ...10 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...
Страница 32: ...32 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...
Страница 54: ...54 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...
Страница 96: ...96 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...
Страница 104: ...104 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...
Страница 108: ...108 SPARC and Netra SPARC T5 Series Servers Administration Guide August 2016 ...