Installing the NIST Label
The NIST identification label must be displayed on each configuration of the
Workstation 6 Series to indicate compliance with NTEP certification.
1.
Place the workstation face down and flat on a hard surface. Ensure that the
integrated magnetic card reader is closest to you.
2.
Remove the NIST identification label from its backing paper, and then apply the
label to the back of the display unit beneath the area where the magnetic card is
swiped. When applying the label, ensure the label is positioned so that the
information reads from left-to-right.
3.
Find and make note of the workstation’s serial number. The serial number can be
found on the Oracle label on the back of the workstation.
4.
Use a black permanent marker to write the serial number in clear legible format on
the NIST identification label after the SERIAL NO text. The serial number must be
permanent.
5.
Let the ink dry for at least 2 hours before proceeding to the next step.
6.
Apply a small piece of cellophane tape over the serial number, making sure to
completely cover the serial number. This is necessary so that the information will
resist standard cleaning of the unit.
7.
Let the label cure for at least 48 hours after applying it to the unit before installing
the unit in a “live” operation setting.