Caution:
Reliable grounding of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (for example, use of power strips).
Caution:
Do not use slide-rail mounted equipment as a shelf.
Guided Maintenance
Guided Maintenance Overview
As a feature of Oracle FS System Manager
(GUI), Guided Maintenance presents
you with a sequence of dialogs that guides you through the process of replacing
field replaceable units (FRUs) and customer replaceable units (CRUs). Prompt
replacement of failed FRUs and CRUs helps maintain system reliability.
Guided Maintenance supports the identification and replacement of FRUs and
CRUs for
Controllers and Drive Enclosures. Guided Maintenance performs the
following functions to help you replace FRUs and CRUs:
•
Determines the status of the hardware based on events and diagnostics to
accurately reflect the sate of the system.
•
Identifies the affected
Controller or Drive Enclosure
. During the identify
process, Guided Maintenance issues a command to light the LEDs on the
affected chassis.
If you are replacing a component on a Drive Enclosure
, the following LEDs
flash:
Drive
Flashes the Locate LED on the Drive Enclosure chassis and the Fault LED on
the selected drive.
Power cooling module
Flashes the Locate LED on the Drive Enclosure chassis and the Fan Fail LED
on the selected power cooling module.
I/O module
Flashes the Locate LED on the Drive Enclosure chassis and the Fault/Locate
LED on the selected I/O module.
If you are replacing a component on the Controller
, the following LEDs
flash:
Energy Storage Module (ESM)
Flashes the Locate LED on the front of the Controller chassis, the Status LED
on the back of the Controller chassis, and the Ready to Remove LED on the
ESM.
All of the remaining Controller components
Flashes the Locate LED on the Controller chassis and the Status LED on the
back of the Controller chassis.
During reverse identify, Guided Maintenance issues a command to light
the LEDs on all of the chassis except for the affected chassis.