Table 2-6 Environmental Specifications for Oracle Exalytics In-Memory
Machine
Component
Description
Environment
•
Operating temperature: 5°C to 35°C (41°F to 95°F) at
sea level; 5°C to 31°C (41°F to 88°F) at altitude
•
Non-operating temperature: -40°C to 68°C (-40°F to
154°F)
•
Operating relative humidity: 10% - 90% relative
humidity, non-condensing
•
Acoustic noise: LwAd: 8.9 B (idle and operating, room
temperature), 8.9 B (maximum ambient); LpAm: 75
dBA (bystander position, maximum ambient)
Power
•
AC power: 200 - 240 VAC
•
Power consumption measurements with CPUs at
maximum utilization:
–
For X6-4, X5-4, and X4-4: 1600W
–
For X3-4: 1467W
–
For X2-4: 1317W
•
Active Idle (operating systems booted and stabilized,
yet running at minimal utilization):
–
For X6-4, X5-4, and X4-4: 723W
–
For X3-4: 723W
–
For X2-4: 663W
Regulations
•
Safety: IEC 60950, UL/CSA 60950. CB Scheme with all
country differences
•
RFI/EMI: FCC CFR 47 Part 15 Class A, EN 55022
Class A, EN 61000-3-2, EN 61000-3-3, EN 300 386
•
Immunity: EN 55024, EN 300 386
Certifications
•
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-
R, S-Mark
•
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC,
GOST-R, BSMI Class A
•
Other: Complies with WEEE Directive (2002/96/EC)
and RoHS Directive (2002/95/EC)
Physical Specifications
•
Weight:
For X6-4, X5-4, and X4-4: 40 kg (88 lb.) maximum
For X3-4: 44 kg (97 lb.) maximum
For X2-4: 38.5 kg (85 lb.) maximum
•
Height: 129.85 mm (5.1 in.)
•
Width: 436.5 mm (17.2 in.)
•
Depth: 732 mm (28.8 in.)
Mounting Option
•
Tool-less rack-mounting slide-rail kit
•
Cable management arm
•
Two 5m InfiniBand cables
2.6 Safety and Compliance Information
For safety and compliance information about your Oracle Exalytics In-Memory
Machine X4-4, see
, and
.
Chapter 2
Safety and Compliance Information
2-6