Customer-Supplied Information

The customer’s network administrator provides the following information:

• Two IP addresses on the provisioning network

• Netmask of the provisioning network

• Default router on the provisioning network

Network Configuration

SM and Sync Network addresses are configured to default values at ExAP or LSMS initialization and
should not need to be changed. If they need to be changed for any reason, refer to sections “Network
Connection” and “Configuration Menu” in the Administration and LNP Feature Activation manual for
ELAP, or the Administration Manual for EPAP.

The provisioning network addresses are configured using the ExAP or LSMS user interface configuration
menu; refer to “Configuration Menu” in the Administration and LNP Feature Activation manual for
ELAP or the Administration Manual for EPAP.

Firewall and Router Filtering Considerations

If a firewall is installed in the provisioning network between the MPS systems or between the MPS
system(s) and the provisioning system, it must be configured to allow selected traffic to pass.

For firewall protocol filtering for the various interfaces, see either the Administration Manual for EPAP
or the Administration and LNP Feature Activation manual for ELAP.

54

910-6535-001 Revision D, February 2014

ExAP or LSMS Network Integration

Hardware and Installation Manual

Содержание E5-APP-B

Страница 1: ...Oracle Communications EAGLE Application B Card Hardware and Installation 910 6535 001 Revision D February 2014...

Страница 2: ...act the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is develop...

Страница 3: ...nd Return 15 Repair and Return Shipping Instructions 16 Locating E5 APP B Card Part Numbers 17 Chapter 2 Safety and Pre Installation Requirements 20 Introduction 21 Safety Information 21 Regulatory Co...

Страница 4: ...tor 40 E5 APP B Card Distance Limitations 40 Installing an E5 APP B Card 41 Removing an E5 APP B Card 44 E5 APP B Card Adapter Interfaces 46 Changing Passwords 47 Appendix A ExAP or LSMS Network Integ...

Страница 5: ...APP B Card In Shelf 31 Figure 8 E5 APP B Card 32 Figure 9 E5 APP B Card Indicators 33 Figure 10 E5 APP B Card Inject Hardware Switch UNLOCKED 41 Figure 11 E5 APP B Card UNLOCKED 42 Figure 12 E5 APP B...

Страница 6: ...Table 3 Basic RMA Types 15 Table 4 RMA Reasons for Return 15 Table 5 Space Requirements 26 Table 6 E5 APP B Card Interfaces 35 Table 7 E5 APP B LED Table 36 Table 8 EPAP Interconnect Table 51 Table 9...

Страница 7: ...Customer Care Center Topics Introduction 8 Where to Find Information in This Manual 8 Related Publications 9 Documentation Availability Packaging and Updates 9 Locate Product Documentation on the Cus...

Страница 8: ...ibes how to use the manual where to find other information how to contact Customer Care Center and Hardware Repair and Return About This Manual Lists general safety instructions that readers should be...

Страница 9: ...ach system and in accordance with contractual agreements For General Availability GA releases Tekelec publishes a complete EAGLE 5 ISS documentation set For Limited Availability LA releases Tekelec ma...

Страница 10: ...wing the document requires Adobe Acrobat Reader which can be downloaded at www adobe com 1 Log into the Tekelec Customer Support site Note If you have not registered for this new site click the Regist...

Страница 11: ...After a CSR is issued the TAC Engineer determines the classification of the trouble If a critical problem exists emergency procedures are initiated If the problem is not critical normal support proced...

Страница 12: ...Colombia Phone 01 800 912 0537 Dominican Republic Phone 1 888 367 8552 Mexico Phone 001 888 367 8552 Peru Phone 0800 53 087 Puerto Rico Phone 1 888 367 8552 Venezuela Phone 0800 176 6497 Europe Middle...

Страница 13: ...gardless of time of day or day of the week as viewed by a customer upon discussion with the supplier For example A loss of service that is comparable to the total loss of effective functional capacity...

Страница 14: ...response is offered by the Tekelec Customer Care Center 24 hours a day 7 days a week The emergency response provides immediate coverage automatic escalation and other features to ensure that the crit...

Страница 15: ...Customer request the replacement of a damaged product Advance Replacement Shipment Within 5 Days After Receipt Customer will return a damaged product for repair Repair Return Depends on Urgency Shipme...

Страница 16: ...ght charges prepaid The assigned RMA number must be clearly printed on the RMA line of the shipping label on the outside of the shipping package If the RMA number is not placed on the label the return...

Страница 17: ...item to the customer a Package the defective component in a suitable package for shipping Use proper static handling procedures b Label the outside and inside of the box with your RMA number clearly v...

Страница 18: ...P B card that needs to be replaced 2 See Locating Drive Module Assembly Part Number Information for the location information of each E5 APP B card on the label Warning Always wear an ESD wrist strap g...

Страница 19: ...tions for illustration Figure 2 Drive Module Label Locations Drive module Assembly 1 CLEI Label 2 Part Number and Revision Label 3 Serial Number Label 4 Locking Screw 5 Warning Always wear an ESD wris...

Страница 20: ...eaders should be familiar with and site Topics Introduction 21 requirements that should be verified before Safety Information 21 installing Tekelec E5 APP B cards into an EAGLE shelf Regulatory Compli...

Страница 21: ...ng container without at least two people to steady any movement of the frame and related components At least two people are required to safely move and position any frame Topple Never pull out the she...

Страница 22: ...vice interruption and takes down the systems Caution This equipment has a connection between the earthed conductor of the DC supply circuit and the earthing conductor Caution The Branch Circuit Overcu...

Страница 23: ...netic Compatibility EMC directive 2004 108 EC Relevant standards in Safety directive 2006 95 EC supported by Certified Body CB Test Certificates issued by the National Certification Body as tested to...

Страница 24: ...eric Site Requirements Ensure that the site where the product will be installed conforms to the specifications listed in the following sections These specifications are standard telephony industry req...

Страница 25: ...ters below sea level at ambient temperature of 30 C 86 F Maximum 4000 meters above sea level at ambient temperature of 40 C 104 F HVAC Requirements Tekelec products are designed to bring cool air in f...

Страница 26: ...f frames listed on the Initial Sales Order Total area per frame 720 square inches 5 0 square feet 0 465 square meters To allow maneuvering frames into place and provide ample 4 feet 1 2 meters Side ai...

Страница 27: ...he central office through the 48VDC return connections located on the breaker panels of each frame Logic Ground Some system types require connection to a logic ground The logic ground path provides a...

Страница 28: ...detailed information in the Power Calculator spreadsheet available on the Tekelec Customer Support site Note Eagle cannot provision two E5 APP B cards running the same application in slots with differ...

Страница 29: ...components and adapter interfaces Topics Introduction 30 E5 APP B Card 30 E5 APP B Card Features 31 E5 APP B Card Components 34 E5 APP B Card Interfaces 34 Electrical Features 35 Mechanical Design an...

Страница 30: ...B cards and highlights E5 APP B card features components and adapter interfaces E5 APP B Card An E5 APP B card comes with two removable drive modules when first ordered A complete shipping package fo...

Страница 31: ...ems The E5 APP B card is a scalable computing platform constructed with state of the art components packaged on a double wide card designed to fit into two slots of an EAGLE shelf Each E5 APP B card h...

Страница 32: ...the corresponding Alarms and Maintenance manual included in this release The other features components are Injector Ejector 2 Ejector Switch 3 Drive module locking switch 5 Switch lock release 6 USB...

Страница 33: ...P B Card Indicators The following light emitting diode LED status indicators see Figure 9 E5 APP B Card Indicators can be found on the E5 APP B card 33 910 6535 001 Revision D February 2014 E5 APP B C...

Страница 34: ...P B card consists of the following standard hardware components Dual Core 2 66GHz 64 bit processor Active Trial BIOS architecture 1333 megahertz MHz processor front side bus speed 8 GB DDR2 DRAM Light...

Страница 35: ...ns and safety precautions in accordance with common standards Mechanical Design and Maintenance Features The E5 APP B card mechanical design meets all applicable NEBS requirements and is designed to p...

Страница 36: ...e Units FRU and operational status of peripheral system components such as cables and connectors through automated testing initiated by FRU components Examples are loop back and link tests Table 7 E5...

Страница 37: ...k LED A1 Amber 1000 Link Speed Green 10 100 Link Speed HW Link LED A2 Amber 1000 Link Speed Green 10 100 Link Speed HW Link LED B1 Amber 1000 Link Speed Green 10 100 Link Speed HW Link LED B2 Amber 10...

Страница 38: ...and installation and removal procedures for the E5 APP B cards Topics Introduction 39 Provisioning Rules for E5 APP B Cards 39 Installing an E5 APP B Card 41 Removing an E5 APP B Card 44 E5 APP B Car...

Страница 39: ...ions i e xx01 xx03 xx05 etc Fan trays 890 0001 xx are required for all EAGLE shelves that host an E5 APP B card Air management cards must be placed in open full height slots within the shelf to provid...

Страница 40: ...l SS005963 to determine if adequate power feeds exist at the customer site For more information on Obtaining the EAGLE Power Calculator see the following section Obtaining the EAGLE Power Calculator T...

Страница 41: ...pper and lower card Inject Eject I E lever release 3 just underneath the I E lever and press it to meet the I E lever This is the mechanical interlock for the card see Figure 12 E5 APP B Card Inject L...

Страница 42: ...Figure 11 E5 APP B Card UNLOCKED 4 Insert the E5 APP B card into the EAGLE shelf 42 910 6535 001 Revision D February 2014 Installing and Removing E5 APP B Cards Hardware and Installation Manual...

Страница 43: ...vers Figure 12 E5 APP B Card Inject Levers This locks the card in place and ensures a strong connection with the pins on the target shelf backplane 6 Slide the E5 APP B H S switch 4 down to the LOCKED...

Страница 44: ...n manual for E5 APP B on halting the E5 APP B Card software 1 On the APP B card slide the Ejector switch 4 up to the UNLOCKED position see Figure 14 E5 APP B Card Eject Hardware Switch UNLOCKED Cautio...

Страница 45: ...red 3 Grasp the upper and lower card Inject Eject I E lever release 3 just underneath the I E lever and press it to meet the I E lever This is the mechanical interlock for the card See Figure 15 E5 A...

Страница 46: ...5 Remove the E5 APP B card from the EAGLE shelf E5 APP B Card Adapter Interfaces The E5 APP B card supports an upper and a lower backplane adapter which supports the following interfaces 1 Gigabit Gb...

Страница 47: ...E5 APP B platforms refer to the application manual for the application loaded on each server Note There should always be a person on site who knows the new passwords If there is a need to contact the...

Страница 48: ...ion for Multi Purpose Server MPS systems Topics Introduction 49 and Oracle Communications LSMS Local Service Management Systems Network Overview 49 Customer Supplied Information 54 Network Configurati...

Страница 49: ...twork Connections Figure 17 ELAP Network Connections and Table 9 ELAP Interconnect Table illustrate the networks and how they are connected All networks except the provisioning network use internal co...

Страница 50: ...Adapter installed in the Lower position odd slot C Adapter installed in the Lower and Upper position even slot D Adapter installed on EAGLE backplane fan Connector Power and Alarm 50 910 6535 001 Rev...

Страница 51: ...ight Switch A Port 3 ETH02 Card Server A Port A P3 830 1102 03 830 1174 XX CAT 5 Straight Switch A Port 4 ETH02 Card Server B Port A P3 830 1102 03 830 1174 XX Cat 5 Straight Switch B Port 3 ETH03 Car...

Страница 52: ...XX Eagle Backplane Fan Connector J3 A 830 1410 XX Card Server B P2 830 1407 XX 830 1413 XX Eagle MMI Port Optional Cable requires adapter 830 1423 XX Card Server B P5 830 1212 XX 52 910 6535 001 Revis...

Страница 53: ...174 XX CAT 5 Straight Switch A Port 3 ETH02 Card Server B Port A P3 830 1102 03 830 1174 XX CAT 5 Straight Switch A Port 4 ETH02 Card Server A Port A P3 830 1102 03 830 1174 XX CAT 5 Straight Switch B...

Страница 54: ...anual for EPAP The provisioning network addresses are configured using the ExAP or LSMS user interface configuration menu refer to Configuration Menu in the Administration and LNP Feature Activation m...

Страница 55: ...l bodies and enterprises Application Server AS A logical entity serving a specific Routing Key An example of an Application Server is a virtual switch element handling all call processing for a unique...

Страница 56: ...shed periodically Digital Signal Level 1 1 544Mbits sec DS1 A widely used standard in telecommunications in North America and Japan to transmit voice and data between devices The data transmitted over...

Страница 57: ...by a technician without having to send the entire product or system to a repair facility G Gigabyte 1 073 741 824 bytes GB I Intelligent Peripheral IP Internet Protocol IP specifies the format of pack...

Страница 58: ...ber Portability Administration Center NPAC and the LNP service databases The LSMS receives LNP data from the NPAC and downloads that data to the service databases LNP data can be entered into the LSMS...

Страница 59: ...d by Bell Labs in the 1970s to standardize equipment that would be installed in a central office This document lists the generic requirements for all new telecommunications equipment systems used in c...

Страница 60: ...Switching Point SSP and the Service Control Point SCP over the network Spanning Tree Protocol T Transmission Control Protocol Internet Protocol TCP IP U User Datagram Protocol UDP Universal Serial Bus...

Отзывы: