• One Server Status indicator (A)
• Four E-Net link and Active LED status indicators (B)
• Two drive module status indicators (C)
• One Card Eject status indicator (D)
For more information about the diagnostics that manage these alarm and status indicators, see
.
E5-APP-B Card Installation
A single E5-APP-B card is installed in two adjacent EAGLE shelf slots. To install two E5-APP-B cards
for redundancy (the recommended configuration), the EAGLE must have room to install two
double-width cards.
E5-APP-B Card Components
The E5-APP-B card consists of the following standard hardware components:
• Dual Core 2.66GHz 64-bit processor
• Active/Trial BIOS architecture
• 1333 megahertz (MHz) processor front side bus speed
• 8 GB DDR2 DRAM
• Light Emitting Diode (LED) status display
• Hardware monitors that read and report:
• Supply and core voltages
• Fan alarm inputs
• Ambient and processor temperatures
• Two drive modules (Field-replaceable Units (FRUs))
E5-APP-B Card Interfaces
The E5-APP-B card includes interfaces for accommodating expansion, control and configuration,
network connectivity, and peripheral support.
Table 6: E5-APP-B Card Interfaces
shows the basic interfaces on the E5-APP-B card.
34
910-6535-001 Revision D, February 2014
E5-APP-B Card Overview
Hardware and Installation Manual