18
Acme Packet 6100 Hardware Installation Guide
with an IEC-60320 C13 connector, connects to the IEC- 60320 C14 receptacle on
the power supply.
DC Power
The Acme Packet 6100 can be powered by central office –48 VDC operations
with a
DC-DC supply. The handle on the front panel of the power supply is used to
insert and remove the power supply from the chassis. The locking handle is
used to lock/unlock the power supply from the chassis. A terminal block on the
DC power supply serves as the DC power interconnect.
Handle to
Remove/Insert
Power Supply
Locking Tab to
Lock/Unlock
Power Supply to
Acme Packet
6100
Figure 2 - 29. Acme Packet 6100 DC Power Supply
DC Power Cords
A DC power cord ships with each DC power supply. A DC power cord must be
3-conductor, 10 AWG minimum rated for at least 140° F (60° C).
Table 2 - 4. Acme Packet 6100 DC Power Cord Wire Markings
Wire Color
Lead Designation (style-A DC
Power Supply)
Lead Designation (style-B DC
Power Supply)
Red
Return
+
Green/Yellow
Frame Ground
Black
-48 VDC
-
Grounding Terminals
The grounding terminals are used to attach the Acme Packet 6100 chassis to a
local earth ground. The terminals are located to the left of Power Supply B on
the rear of the Acme Packet 6100. The Acme Packet 6100 is shipped with a lug
and mounting nuts attached to the chassis along with a pre-made ground
Содержание Acme Packet 6100
Страница 1: ...Acme Packet 6100 Hardware Installation Guide Regulatory Model AP6100 January 2014...
Страница 6: ...vi Acme Packet 6100 Hardware Installation Guide...
Страница 8: ...viii Acme Packet 6100 Hardware Installation Guide...
Страница 12: ...4 Acme Packet 6100 Hardware Installation Guide...
Страница 36: ...28 Acme Packet 6100 Hardware Installation Guide...
Страница 66: ...58 Acme Packet 6100 Hardware Installation Guide...
Страница 96: ...88 Acme Packet 6100 Hardware Installation Guide...
Страница 106: ...98 Acme Packet 6100 Hardware Installation Guide...