4.

 

INSERTING THE CARD 

The card occupies one slot on the 

matrix. 
To insert the card proceed as 

follows: 
1)

 

Disconnect the power supply 

to the unit (POWER SUPPLY 1 

and POWER SUPPLY 2 strips). 

2)

 

Remove the rear blank plate 

for the slot where the card is 

to be inserted. 

3)

 

Insert the card by fitting it 

into the slot guides and 

fasten it  by means of the 

fastening screws. 

4)

 

Reconnect the power. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Figure 5 

Figure 3 

Figure 4 

 

Содержание UMX-ETH+

Страница 1: ...9I012M May 2018 V4 3 000...

Страница 2: ......

Страница 3: ...MISSIONING THE UNIT 7 5 1 Configuration of the UMX ETH network addresses 7 6 OPTIMAX2 SYSTEM NETWORK SPECIFICATIONS 8 7 TECHNICAL SPECIFICATIONS 10 8 SOFTWARE AND FIRMWARE VERSIONS 10 9 DOCUMENT VERSI...

Страница 4: ...e operation of the equipment using software and or basic TELNET or SSH Secure Shell functions Each card occupies one position on the bus of a UMX 03 0 Files download by means of FTP or FTP S 2 ELEMENT...

Страница 5: ...g periods remove the battery Remove leaking batteries from the device immediately If battery acid leaks out it is essential to avoid contact with the skin eyes and mucous membranes If the acid does co...

Страница 6: ...o insert the card proceed as follows 1 Disconnect the power supply to the unit POWER SUPPLY 1 and POWER SUPPLY 2 strips 2 Remove the rear blank plate for the slot where the card is to be inserted 3 In...

Страница 7: ...C open a browser enter the IP address for the UMX ETH card and press INTRO By default the IP address is 10 1 1 1 Warning The range of IP addresses for the unit and the PC must match Otherwise the netw...

Страница 8: ...crophone to the Optimax 2 matrixes point to multipoint communication VoIP OPTIMAX2 matrix allows to work also like a receiving VoIP terminal one call each time as following standards Call establishing...

Страница 9: ...ON TCP unicast 28000 Integration SNMP UDP unicast 161 162 TRAPS Integration SIP UDP unicast 5060 Control 5078 RTP Audio Specifications of the local network LAN Bandwidth 1 Mb for each audio channel Nu...

Страница 10: ...03 0 Consumption 300 mA 8 SOFTWARE AND FIRMWARE VERSIONS The functionalities described in this user manual are valid for software and firmware versions that are the same or later versions of UMX ETH F...

Страница 11: ...e of the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or pur...

Страница 12: ...9I012M V4 3 100 May 2018...