1. 

Intended Use 

The product is intended to charge and discharge NiCd, NiMH or 3.7v Li-ion 

rechargeable batteries in size type of 16340, 10440, 14500, 16340, 18500, 

18650,  26650,  26500.  It  provides  four  independent  charging  slots  for 

rechargeable  batteries.  The  charger  can  also  optimize  and  test  the 

maximum  capacity  of  rechargeable  batteries.  Each  charging  slot  has  its 

own display showing various information: charging current, battery voltage, 

charged capacity, battery internal resistance and elapsed charging time. 

Charging  current  can  be  selected  for  200mA,  300mA,  500mA  ,  700mA, 

and 1000mA ( if only bay 1 and/or 4 are used to charging batteries, current 

1500mA and 2000mA    can be further selected).   

Default  charging  current  is  500mA.  For  Ni-MH  or  Ni-Cd  batteries,  the 

maximum discharging current is 700mA( when 1000mA charging current is 

selected  with  TEST  or  REFRESH  mode,  the  discharging  current  is  still 

700mA). 

Discharging  current  can  be  selected  between  200mA,  300mA,  500mA, 

700mA and 1000mA for Li-ion batteries.   

Default charging or discharging current is 500mA 

   

The  charger  can  charge  batteries  of  different  type  and  size  and  with 

different  capacity  at  the  same  time.  It  also  integrates  the  minus  delta 

voltage (-ΔV) for NiCd or NiMh battery charging termination, and for Li-ion 

batteries  charging  to  4.2V  with  pre-selected  CC/CV  standard  lithium 

charging algorithm.   

When  battery  is  fully  charged,  the  charger  will  switch  to  trickle  charging 

automatically for NiCd, NiMH rechargeable batteries, therefore battery will 

be  kept  at  its  optimum  capacity.  With  Lithium  battery,  there  is  no  trickle 

charge current when charging is completed due to maintain battery safety 

reason.  However  when  li-ion  batteries  voltage  is  dropped  below  4.12v, 

charger will start charging batteries to full automatically.     

Charger also includes overheat detection to protect rechargeable batteries 

and  charger  itself  from  overheating.  When  temperature  sensor  detects 

PCB  or battery  voltage  is  over 40  degrees  Celsius,  then  ventilation    fan 

will  be  turned  on  automatically.  Only  when  all  6  temperature  sensors 

temperature is measured less than 40 degrees Celsius, then the fan will be 

switched off.   

The  charger  can  only  be  powered  by  power  supply  rated  12v/3.0A. 

Operate and store it in dry indoor environment only. 

This  product  fulfills  European  and  national  requirements  related  to 

electromagnetic compatibility (EMC). CE conformity has been verified and 

the relevant statements are available upon request. 

Unauthorized  conversion  and/or  modification  of  the  device  are 

inadmissible  because  of  safety  and  approval  reasons  (CE).  Any  usage 

other than described above is not permitted and can damage the product 

and lead to associated risks such as short-circuit, fire, electric shock, etc. 

Please read the operating instructions thoroughly and keep them for future 

reference. 

The charger has its backlight turned on after each key press. Back light will 

be switched off after 30 seconds when no key is pressed. 

The maximum charging capacity can be up to 20,000mAH. 

 

2. 

Delivery Content 

Battery Charger BT-C3100     

1pcs 

Power Adapter 

 

 

 

1pcs 

Operation Instructions   

 

1pcs 

 

3. 

Safety Instructions

               

 

We do not assume liability for resulting damages to property or personal 

injury if the product has been abused in any way or damaged by improper 

use  or  failure  to  observe  these  operating  instructions.  The  warranty  will 

then expire! 

3.1 Product Safety 

 

The product must not be exposed to substantial mechanical strain or 

strong vibrations. 

 

The product must be protected against electromagnetic fields, static 

electrical fields, extreme temperatures, direct sunlight and moisture 

 

The manufacturer’s  instruction  for the  respective  batteries  must  be 

observed, before they are charged. 

 

The product should not be connected immediately after it has been 

brought  from  an  area  of  cold  temperature  to  an  area  of  warm 

temperature. Condensed water might destroy the product. Wait until 

the product adapts to the new ambient temperature before use. 

Sufficient ventilation is essential when operating the charger. Never cover 

the ventilating slots of the charger, especially area in front of the cooling 

fan need to be at least 8cm free open area for enough ventilation purpose.   

Please  take  cautions  especially  when  ambient  temperature  is  over  35 

degrees Celsius and charging current rate is over 0.5C. If higher charging 

current applied, it is more easy to build up temperature on batteries. 

 

3.2    Battery Safety 

 

Correct polarity must be observed while inserting the batteries. 

 

Non-rechargeable batteries,  rechargeable alkaline batteries  (RAM), 