background image

ACCTRS232K 

 

                                    RS232 Interface Kit 

 

 

   

 

 

 

 

          ACCTRS232K-MAD-ED2016-10-A 

I

 

 

Quick Reference/ Kurzanleitung 

 

Scope of Supply/ Lieferumfang 

 

  RS232 interface board incl. terminal block/ RS232 Interface-Platine inkl. 

Anschlussklemmblock 

  Software CD 

  RS232 interface cable/ RS232 Schnittstellenkabel (1,5 m)

 

 

  Cable gland/ Kabelverschraubung M12x1,5 

  Mounting screws, cable tie/ Schrauben, Kabelbinder 

  Quick reference/ Kurzanleitung 

 
 

 

 

 

 

 

 

 

 

      Installation of the RS232 interface board/ 

 

 

 

 

 

 

 

 

      Einbau der RS232-Interface-Platine 

 

Installation 

 

  Please plug the RS232 interface into the place provided, which is located beside the display. In the correct position the holes of the 

interface match with the thread holes of the CT box. 

  Now press the PCB down to connect it with the CT. Use both M3x5 screws for fixing the board. Exchange the blind screw on the CT box 

by the cable gland and install the RS232 interface cable. 

  Make sure the wiring is correct according to the drawing and designation printed on the interface board. 

  The CT always needs an external power supply for operation. 

  Please install the software as described in the operators manual. Follow the software instruction manual. After you have connected the 

RS232 cable to your PC and started the software the communication will be established. 

 

NOTE:

 Please make sure that the option 

Scan non-USB devices

 is activated in the software 

[Menu: Preferences/ Options].

 

 
 