Optoelectronics OPI-4012 Скачать руководство пользователя страница 1

5J0xxx / DM-070xxxx 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

(Tentative)

 

 

 

 

 

 

 

 

 

 

 

OPTOELECTRONICS Co., Ltd.

This specification is subject to change at any time without prior notice

 

 

 

 

 

 

OPI-4012 

 

Wireless 1D/2D Imager 

Instruction Manual 

Содержание OPI-4012

Страница 1: ...5J0xxx DM 070xxxx Tentative OPTOELECTRONICS Co Ltd Thisspecificationissubjecttochangeatanytimewithoutpriornotice OPI 4012 Wireless 1D 2D Imager Instruction Manual ...

Страница 2: ...quality accuracy or fitness for any particular part of this document In no event shall the manufacturer be liable for direct indirect special incidentalorconsequentialdamages arisingfromany defect orerror inthis document Theinformationinthisdocumentissubjecttochange without notice This document contains materials protected under International Copyright Laws All rights reserved No part of this manu...

Страница 3: ...Safety 3 2 Handling Precautions 6 3 Package Contents 8 4 Detailed View 9 5 Getting Started 11 6 Scanning Barcodes 13 7 Wireless Communication 14 8 How to Configure the Wireless Communication Settings 18 9 Default Settings 21 10 Menu Barcodes 23 ...

Страница 4: ...nner there is the potential for serious injury or death If you ignore the warning described and operate the product in an improper manner there is a danger of serious bodily injury or damage to the product and or the environment If you ignore the caution described and operate the product in an improper manner there is the potential for damage to the product A triangle indicates something you shoul...

Страница 5: ... not use this device in the following areas Doing so may cause fire electric shock malfunction orradiointerference Inareasexposedtodirectsunlightforlongperiodsoftime Industyenvironments Nearwaterorinextremelyhighhumidityorotherliquids Near heat sources such as radiators heat registers stoves or other types of apparatus thatproduceheat Near microwaves medical devices or low power radio stations Rea...

Страница 6: ...elerantforthefire Do not short the power leads on the battery pack If the and terminals come in contact with metals such as a necklace or hairpin short circuiting occurs Setthebatterypackasindicatedonthebatterylabel If liquid from a leaking battery pack gets in the eyes wash them with clean water and consultaphysicianimmediately CAUTION Check the local regulations for proper battery disposal This ...

Страница 7: ...erefore itdoesnothave radiostation licenseinJapan Thefollowing activities are prohibited undertheRadio Law Remodeling anddisassembly Peeling off the certificate label 2 3 Bluetooth Bluetooth is atrademarkowned byitsproprietor and usedby OPTOELECTRONICS Co Ltd underlicense To communicate via Bluetooth the device which the OPI 4012 is connected to must support the same Bluetooth version and profile ...

Страница 8: ...actories specific power saving radio stations requiringnolicense and amatuer radio stations are managed Please make sure that other radio stations are not managed in the frequency band 2 4 gHz before using this device If radio interference occurs between this device and other radio stations change the service space immediately orstoptransmitting radiowavesto avoid the interference If you haveany q...

Страница 9: ...e followingitems before gettingstarted 1scanner OPI 4012 with anembedded battery pack 1handstrap 1 copy of Instruction manual 1dedicated ACadapter 9 Thenumberofaccessories maydiffer depending on the productspecification 9 Please contactthe nearest dealer ifaccessoriesare damaged or missing ...

Страница 10: ...r 6 HandStrapHook Thosehooksarenecessarytoattachahandstrap 7 BuzzerHole Buzzer sounds through the buzzer hole 8 StatusLED The status LED is used to alert users to the status of the scanning operation wireless connectivity data storage remaining battery level and recharging time 9 DCJackCover A cover to protect DC jack Open the cover when charging the scanner using a dedicated AC adapter 10 Electri...

Страница 11: ...e Functions 1 SerialLabel 2 Electrical Terminal 3 Electrical Terminal Charging terminals are used to supply power to the scanner from a dedicated cradle CHG 4001 4 DCJack Connect adedicatedACadapter 5 ACAdapterCableGuide InstalladedicatedACadaptercablealongtheguide ...

Страница 12: ...issionwas executednormally Yes Red Blinking Showsthatthedatacouldnotbetransmitted Yes Scanning Orange Blinking Showsthatthedataisbeingstoredinmemory Yes Green Continuously Blinking Showsthat aBluetoothconnectionis beingmade No Green Lighting Showsthat aBluetoothconnectionismade Yes Bluetooth Connection Red Lighting ShowsthatthescannerfailedtomakeaBluetooth connection Yes Red Lighting Showsthatthes...

Страница 13: ...12 Charging the scanner its mainbattery on the CHG 4001cradle Replacing battery Removing battery Placing battery Electricalcontacts Switchfor terminal detection Scanneronthecradle Concave 凹 ...

Страница 14: ...meet To scan a barcode within the aiming range make sure that two central LED light patterns overlap then place thecenterof theoverlappingLEDlight patternson the centerof the barcode To scan a barcode wider than a width of the aiming range aim at the barcode from further away Make sure that the barcodeisbetween two LEDlight patterns onboththeright andleft 9 Scanning performance may decline due to ...

Страница 15: ...d Adaptation Protocol RFCOMM RS 232C Emulation Profile GAP Generic Access Profile SPP Serial Port Profile TransmissionPower Class 2 Communication Configuration 1 Scanner OPI 4012 to 1 Host 9 It is not possible to connect more than one scanner to one host Communication Mode Scanner OPI 4012 Master Bluetooth device Slave LowPower Mode Sniff mode is not supported Data Security Encryption and authenti...

Страница 16: ...oth devices to one OPI 4012 scanner 9 If you scan a wrong menu barcode please start the setting from the beginning Bluetooth Security Settings Carry out this setting to provide safe connection between the scanner and the Bluetooth device You must carry out authentication within 30 seconds Please input the PIN code within the 30 seconds 9 When the authentication is enabled please set the PIN code b...

Страница 17: ...riggerswitch time toconnect Press triggerswitch time to disconnect Auto disconnect Auto reconnect Auto Connect You can set the scanner to automatically connect after setting the Bluetooth device address Data memorizing Scanned barcode data will be stored in a memory automatically when the data memorizing setting is enabled The capacity of the memory is about 100KB When the memory get full while th...

Страница 18: ...h timeto disconnect This is the time the trigger switch needs to be pressed where after the scanner disconnects Autodisconnect If the scanner is idle for configured time it will be disconnected Autoreconnect If the scanner is disconnected because it is out side of the communication range the reader will try to establish connection during the configured time Default setting S0 Foregoing settings ar...

Страница 19: ...oth device address Press triggerkeyfortheset duration Scan Manuallyconnect menubarcode CONN 4 TheLEDof thescannerblinksgreenlightand makeconnection 5 Once the scanner makes connectionsuccessfully the LEDturnssolidgreen and thescannersoundsa buzzer If the scanner fails in making connection the LED of the scanner blinks red light and the scanner sounds a warning buzzer 6 You will be abletoscanbarcod...

Страница 20: ...theBluetooth deviceas follows Scan a12 digitBluetooth device address Press triggerkeyfortheset duration Scan Manuallyconnect menubarcode CONN 4 TheLEDof thescannerblinksgreenlightand makeconnection 5 Input the same PINcode tothe Bluetoothdevice 6 Once the scanner makes connectionsuccessfully the LEDturnssolidgreen and thescannersoundsa buzzer If the scanner fails in making connection the LED of th...

Страница 21: ...d andthe scannersoundsabuzzer When the scannercarriesoutascanning operation outsideofthecommunicationrange the LED ofthescanner turns orange andthebuzzer soundchanges When the scanneris setto data memorizingdisabled thescannerwillnotcarryout scanning operation outsideof thecommunication range When the memoryofthescannergetsfull while the scanneris outside ofthecommunication range you will not be a...

Страница 22: ... E UPC E1 CR UPC EAdd on CR EAN 13 CR EAN 13Add on CR EAN 8 CR EAN 8Add on CR CODE 39 Nottransmit ST SP CR Tri Optic Nottransmit ST SP CR NW 7 CODABAR Nottransmit ST SP CR Industrial2of5 CR Interleaved2of5 CR Matrix2of5 ChinesePostmatrix2of5 CR Korean Postal Authority code CR S CODE CR Telepen CR CODE 93 CR CODE 128 CR MSI Plessey CR UK Plessey CR IATA CR PDF417 CR MicroPDF417 CR QRCODE MicroQR CR...

Страница 23: ...CB CR RSS 14CCA RSS 14CCB RSSLimitedCCA RSSLimitedCCB RSSExpandedCCA Composite RSS RSSExpandedCCB CR UCC EAN 128 CCA UCC EAN 128 CCB Composite UCC EAN 128 UCC EAN 128 CCC CR Note 1 Inthecolumnof Reading means Enabletoread and means Disabletoread 2 Inthecolumnof Transmit codelength means Transmitcodelength and means Nottransmitcodelength 3 Inthecolumnof TransmitCD means Transmitcheckdigit means Not...

Страница 24: ...bled Autodisconnect Disabled Autoreconnect 5minutes ACK NAK NoHandshake ACK NAKTimeout 1second Wireless Communication Settings PINCode Enabled last4digitsoftheBDaddress Autoconnect Enabled Authentication Enabled authenticationifnotpaired Bluetooth Connection Setting Encryption Disabled 10 Menu Barcodes ThissectioncontainsthemenubarcodesoftheOPI 4012defaultsettings Other menu labels are listed in t...

Страница 25: ...24 Menu Barcodes ...

Страница 26: ... label SET ZZ _Z7_ CNPC Connect to PC _CNPC_ Connect to CNCR Connect to Cradle _CNCR_ END ZZ _ZZ_ CODE39 labels QR code label SET ZZ _ZZ_ BDAS Set Bluetooth address _BDAS_ Bluetooth address setting BDAE End Bluetooth address _BDAE_ END ZZ _ZZ_ ...

Страница 27: ...dress setting 0 _Q0_ 9 _Q9_ 1 _Q1_ A _0A_ 2 _Q2_ B _0B_ 3 _Q3_ C _0C_ 4 _Q4_ D _0D_ 5 _Q5_ E _0E_ 6 _Q6_ F _0F_ 7 _Q7_ 8 _Q8_ Flow ZZ BDAS 12Digit Bluetooth address BDAE ZZ In case reading wrong address restart from reading BDAS ...

Страница 28: ...ODE39 labels QR code label SET ZZ _ZZ_ AUTE Enable _AUTE_ Authentication AUTD Disable _AUTD_ END ZZ _ZZ_ CODE39 labels QR code label SET ZZ _ZZ_ ENCE Enable _ENCE_ Encryption ENCD Disable _ENCD_ END ZZ _ZZ_ ...

Страница 29: ...28 CODE39 labels QR code label SET ZZ _ZZ_ PINS Set PIN code setting _PINS_ 0 _Q0_ 1 _Q1_ 2 _Q2_ 3 _Q3_ 4 _Q4_ 5 _Q5_ 6 _Q6_ 7 _Q7_ 8 _Q8_ 9 _Q9_ PIN code PINE End PIN code setting _PINE_ END ZZ _ZZ_ ...

Страница 30: ...ZZ_ Connection Disconnection Manually connect CONN _ CONN _ Manually disconnect DISC _ DISC _ Default Interface CODE39 labels QR code label SET ZZ _ZZ_ Default SO _SO_ END ZZ _ZZ_ OPTOELECTRONICS Co Ltd OPI 4012InstructionManual Marketing Group 12 17 Tsukagoshi4 chome Warabi Saitama335 0002Japan TEL 81 48 446 1183 FAX 81 48 434 2820 ...

Страница 31: ...which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienc...