V 1.0 - eng
42
COE LS-X Line Scan Camera | USER MANUAL
The
Line Inverter
parameter is disabled by default.
8.2.2 Enable Strobe Signal
The strobe signal is used to directly output signals to external devices. The camera
supports synchronous signals when it outputs one frame or one line image.
⚫
If you need to let the camera output a signal for each frame image output, follow steps below
to set it.
Steps:
1. Click
Digital IO Control
, and set
Exposure Start Active
as
Line Source
.
2. Select
Frame Mode
as
Strobe Source Selector
.
3. Enable
Strobe Enable
.
Figure 1-41
Set Frame Mode
⚫
If you need to let the camera output a signal for each line image output, follow steps below to
set it.
Steps:
1. Click
Digital IO Control
, and select
Line Mode
as
Strobe Source Selector
.
2. Set
Line Source
according to actual demands.
3. Enable
Strobe Enable
.