V 1.0 - eng
34
COE LS-X Line Scan Camera | USER MANUAL
Figure 1-25
Set Burst Frame Count
When
Acquisition Burst Frame Count
is 1, it is in single frame trigger mode. When
Acquisition
Burst Frame Count
is larger than 1, it is in multi-frame trigger mode. If
Acquisition Burst Frame
Count
is n and when inputting 1 trigger signal, the camera stops acquiring images after exposing n
times and outputs n frame images. The sequence diagram of burst frame count is shown below.
Figure 1-26
Sequence Diagram
The sequence diagram above uses rising edge as trigger activation, and the camera’s height
parameter is 4.
7.6.2 Trigger Activation
The camera supports trigger acquisition in the rising edge, falling edge, any edge, level high or
level low of the external signal. The principle and parameter of trigger activation are shown below.
Table 1-12
Trigger Activation Description and Parameter
Trigger
Activation
Parameter
Parameter
Value
Description
Rising Edge
Acquisition Control >
Trigger Activation
Rising Edge
The camera triggers only when
receiveing a rising edge.
Falling Edge
Acquisition Control >
Trigger Activation
Falling Edge
The camera triggers only when
receiveing a falling edge.
Any Edge
Acquisition Control >
Trigger Activation
Any Edge
The camera triggers when
receiveing a rising edge or a falling
edge.