background image

Version 1.0.1 - 2020-04-09

14

Montageanleitung

GU 5 | GU 5-H

EN

GU5_G

U5-H_G

B_5.

fm

5

Maintenance

5.1

Inspection and maintenance

The type and level of wear depends to a large extent on the individual usage and operating
conditions. Any indicated intervals therefore are only valid for the corresponding approved
conditions. 

Maintenance work must be carried out in a room with filtered forced ventilation.

6

Malfunctions

Interval

Where?

What?

How?

Start of work,
after every main-
tenance or repair 
work

after empirical 
values on the 
part of the opera-
tor

Co

llectio

n tan

k

Emptying

Empty the collection tank regularly.

If the suction per-
formance redu-
ces.

after empirical 
values on the 
part of the opera-
tor

Ex

ha

us

t ai

r

Cleaning

Replacing

Wash the exhaust air filter with water, dry and reinsert.

If necessary, replace the exhaust air filter.

after empirical 
values on the 
part of the opera-
tor

C

y

cl

on

e se

p

a

ra

tor

Check

Cleaning

Checks should be carried out at regular intervals if par-
ticles have deposited inside the device, e.g. in the cyclone 
separator. These must be removed.

Annually

A

m

bien

t air

Hazardous 
substances 
exposure

Local measurements for particulate hazardous 
substances.

every 3 years

Local measurements for pure gaseous substances.

Malfunction

Cause/
possible effects

Solution

Do not switch on the 
blower fans.

Incorrect socket used.

Neutral conductor N not present

Use a 5-pin 3-phase current - Use an 
extension cable.

400 V power supply cable not executed 
as 5-pin.

Содержание 3107114

Страница 1: ...EN Operating Manual Extraction unit Version 1 0 1 Item no 3107124 GU 5 H GU 5 Item no 3107114 GU 5 GU 5 H...

Страница 2: ...Unpacking 11 3 4 Commissioning 11 4 Operation 4 1 Extraction unit function description 12 4 2 Functional Description of the Electrical Connections 12 4 3 General information 12 4 4 Fire and Explosion...

Страница 3: ...nce all maintenance works and functional tests are described which the operator must perform in regular intervals The illustration and information included in the present manual can possibly deviate f...

Страница 4: ...icable regulations of each country must be observed If necessary relevant measures must be taken to comply with national regulations before commissioning the extraction unit Always keep this documenta...

Страница 5: ...s INFORMATION Practical tips and other important or useful information and notes No dangerous or harmful consequences for people or objects In case of specific dangers we replace the pictogram with or...

Страница 6: ...for all occupational exposure limit values as well as for non flammable dust with carcinogenic substances The clean air is emitted back to the location Use in dust areas with potentially explosive atm...

Страница 7: ...ility that potentially toxic highly toxic carcinogenic mutagenic or reprotoxic substances are released further protective measures are necessary according to 10 of the German Ordinance on Hazardous Su...

Страница 8: ...ioning if the manufacturer or installer has confirmed to the operator that the electrical system and operating materials have been procured in accordance with the stipulations of the accident preventi...

Страница 9: ...more the noise emission also depends on production engineering factors e g speed material and clamping conditions INFORMATION The mentioned numerical value is the emission level Electrical connection...

Страница 10: ...damping behaviour other noise sources e g the number of machines other processes taking place in proximity and the period of time during which the operator is exposed to the noise Furthermore it is po...

Страница 11: ...y occur if parts of the machine tumble or fall down from the forklift truck or from the transport vehicle Follow the instructions and information on the transport box 3 3 Unpacking Install the extract...

Страница 12: ...er fans switch off as soon as machine or device connected to the 400 V socket is switched off INFORMATION The blower fans switch on only when the possible extension cable used or the 400 V socket have...

Страница 13: ...air loose clothing fingers and other body parts away from the openings and moving parts of the device Do not use the device if the power cable or connector are damaged The power cable must be checked...

Страница 14: ...nce redu ces after empirical values on the part of the opera tor Exhaust air Cleaning Replacing Wash the exhaust air filter with water dry and reinsert If necessary replace the exhaust air filter afte...

Страница 15: ...we are not able to perform any services Defects resulting from the following circumstances are excluded from liability and warranty claims Use of the product beyond the technological capability and i...

Страница 16: ...as household waste According to the European directive 2011 65 EG regarding disused electrical and electronic devices and the implementation in national law disused electrical tools and electrical equ...

Страница 17: ...s on the type plate 8 2 Elektrische Ersatzteile Electrical spare parts 8 2 1 Schaltplan Wiring diagram Der aktuelle Schaltplan mit Ersatzteilliste befindet sich im Schaltschrank der Maschine oder befi...

Страница 18: ...05 6 Dichtung Seal 1 0310711406 7 Beh lter Vessel 1 0310711407 8 Knopf Knob 1 0310711408 9 Verschlussschraube Locking screw 4 0310711409 10 Filter Filter 1 0310711410 11 Abdeckung Cover 1 0310711411 1...

Страница 19: ...diagram power distribution Anschl sse Connections A Anschluss Schleifmaschine Grinding machine connection CEE 400V 16A B 230V Schutzkontaktsteckdose 230 V socket with earthing contact C Versorgungsan...

Страница 20: ...substances in electrical and elect ronic equipment 2015 863 EU The following harmonized standards were applied EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirement...

Страница 21: ...5 GU 5 H EN GU5_GU5 H_GBSIX fm Index C Copyright 15 E Electrical connection 9 I Inspection deadlines 8 L Liability claims for defects 15 M Malfunctions 14 S Safety instructions 4 T Technical specifica...

Страница 22: ...Version 1 0 1 2020 04 09 22 Translation of original instruction GU 5 GU 5 H EN GU5_GU5 H_GBSIX fm...

Отзывы: