background image

User

’s Manual

                                                                                                           

Version 1.5 

 
 
 
 
 
 
 
 
 

OMM-1000 

  Multi-format matrix

 

16x16 DVI / HDMI / SDI / DisplayPort Matrix 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Doc No. : OM-D150512 / Rev1.5 

Содержание OMM-1000

Страница 1: ...User s Manual Version 1 5 OMM 1000 Multi format matrix 16x16 DVI HDMI SDI DisplayPort Matrix Doc No OM D150512 Rev1 5 ...

Страница 2: ...11 3 3 FUNCTION mode 11 3 3 1 Gateway 12 3 3 2 Subnet Mask 12 3 3 3 IP Address 12 3 3 4 MAC Address 13 3 3 5 UDP Port Number 13 3 3 6 Multi Viewer 14 3 3 7 Video Generator 14 3 3 8 Monitoring Output 15 3 3 9 EDID Configure 15 3 3 10 Baud Rate 16 3 3 11 Control Lock 17 3 3 12 Reset Mode 17 3 4 Preset mode 118 Chapter 4 PC program operation 19 4 1 Basic setup 20 4 1 1 Connect Info 20 4 1 2 Channel N...

Страница 3: ...equest 34 6 2 10 Control lock command 35 6 2 11 Preset Control command 35 Chapter 7 Firmware update 36 Chapter 8 Trouble shooting 39 Chapter 9 Specification 40 9 1 General specification 40 9 2 Power Specification 41 9 3 SDI video input and output scaling condition 41 9 4 Compatibility between Dual link DVI In Output cards and other In Output cards 42 9 5 Compatibility between DisplayPort In Output...

Страница 4: ...SDI is not a licensed HDCP interface and if the content received from HDMI is protected by HDCP there should be no output from the SDI slot 1 1 Key features Up to 16 DVI HDMI SDI and DisplayPort inputs and outputs can be configured Each card has 4 input or 4 output ports and 4 cards can be fitted into input and output bays Dual link DVI supports from 2 x 2 to 8 x8 input and output Has Electrical D...

Страница 5: ...k DVI output card SDVI 1FI 4 ports 1 fiber optical DVI input card SDVI 1FO 4 ports 1 fiber optical DVI output card HDMI 4EI 4 ports electrical HDMI input card HDMI 4EI 4 ports electrical HDMI output card SDI 4EI 4 ports electrical SDI input card SDI 4EO 4 ports electrical SDI output card DP1 4EI 4 ports electrical DisplayPort input card DP1 4EO 4 ports electrical DisplayPort output card QDVI O Mul...

Страница 6: ...d on the front panel as shown in Figure 1 1 Figure 1 1 Front panel of OMM 1000 All Input and output cards interface ports and power supplier are placed on the rear panel as below Input bay for 4 input cards left side Output bay for 4 output cards right side Input and Out bay for 2 in output cards Only Dual link cards SERVICE RJ 11 receptacle for firmware upgrade RS 232 Serial communication port LA...

Страница 7: ...NOTE Typically the IP address of PC connected to the network is configured by DHCP server But if the PC is connected directly to the OMM 1000 the network server will not able to assign the IP address In this case network information of PC should be set manually The default IP address of OMM 1000 is 192 168 1 117 Before connecting OMM 1000 to your network please verify the availability of IP addres...

Страница 8: ...nd store optimized EDID in input port to avoid any compliance problems in the field Figure 1 3 Concept of EDID setting and working in OMM 1000 modular matrix As depicted in Figure 1 3 once EDID is configured each EDID is stored in EEPROM in Input ports As a result the video sources are able to read EDID from the EEPROM during booting process even though the OMM 1000 and connected displays are not ...

Страница 9: ...ocal Area Connection and right click to open property Select Internet Protocol Version 4 TCP IPv4 Enter IP Subnet mask Gateway and DNS server address compatible with the current network setting of OMM 1000 Click OK to terminate IP setup session Note If the IP address of OMM 1000 is 192 168 001 117 the PC IP address should be chosen as 192 168 001 nnn where nnn can range from 000 to 255 except 117 ...

Страница 10: ... and choose an icon in Connection Description window and click OK In Connect To window ignore the Country Area Code and Phone Number fields but select available COM port of PC to be connected to OMM 1000 then click OK In COM Properties window set the parameters as below Bits per second baud rate 115200 115200 is default baud rate of OMM 1000 Data bits 8 Parity None Stop bits 1 Flow control None No...

Страница 11: ...Input output connection repeat steps 1 to 5 3 2 UNLINK mode It unlinks input output connection 1 Press SHIFT key button 2 Press LINK key button 3 Press the input key button to be disconnected 4 Press ENTER key button 3 3 FUNCTION mode It configures basic setting of OMM 1000 to be controlled by command input and PC program Press FUNCTION to see features FUNCTION key button will cycle the following ...

Страница 12: ...mes The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right Subnet Mask O 255 255 255 000 N 255 255 255 000 Modify the Subnet mask address to be used for your network Press ENTER key button to complete the process The default setting is 255 255 255 000 3 3 3 IP Addres...

Страница 13: ...NTER key button to complete the process 3 3 5 UDP Port Number Press FUNCTION key button five times It makes number setting data range from 0 to 65535 The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right Function Mode Port Number Old data 03000 New data 03000 Modify...

Страница 14: ...s inserted among output slots If only one QDVI O is inserted the number will be fixed and not changed 2 Select the output resolution 3 Select Layout 4 Press ENTER key button to complete the process 3 3 7 Video Generator Press FUNCTION key button seven times It changes resolution and pattern of video generator The cursor shows that it is selected and activated Input 1 and 2 key buttons move the men...

Страница 15: ...ID Configure Press FUNCTION key button nine times It sets EDID information in input port OMM 1000 supports three types of EDID setting Default Mode Auto Mix Mode and Output Copy Mode For more information refer to Chap 5 2 The cursor shows that it is selected and activated Input 1 and 2 key buttons select YES and NO Input 3 and 4 key buttons move left and right Change EDID mode Input 5 and 6 key bu...

Страница 16: ...aved in allocated input 3 3 If you select Output Copy Mode OMM 1000 reads EDID from any target displays and copies it in allocated input Note There is Edit Data Mode but it is used to modify existing EDID to make new EDID working with specific systems It is not recommended for general user For further information please contact techsupp opticis com 3 3 10Baud Rate Press FUNCTION key button ten tim...

Страница 17: ...ata Lock UnLock Key Lock UnLock Input 1 and 2 key buttons move the cursor up and down Input 3 key button moves Lock Input 4 key button moves UnLock Press ENTER key button to complete the process 3 3 12Reset Mode Press FUNCTION key button twelve times It resets OMM 1000 It starts rebooting and restores all default setting Press Input 1 key button to complete the process ...

Страница 18: ...vated Select a preset number by pressing input 3 or 4 key button Press Input 1 key button to save the preset number and it saves the current routings status If you want to save another routings please configure and save another Link connection at Link mode Preset Load mode The cursor shows that it is selected and activated Select a preset number by pressing input 3 or 4 key button Press Input 1 ke...

Страница 19: ...ick it to launch PC program for OMM 1000 The PC program provides a user friendly graphic interface alternative to key button input and command input operation Copy OMM ver1 x exe file in any directories in your PC and double click it to run Then initial window of PC program for OMM 1000 as below will open Fig 4 1 PC program of OMM 1000 ...

Страница 20: ...hernet UDP by click the radio buttons In case of RS 232 control enter available COM port number of your PC and select baud rate The baud rate should be same as that OMM 1000 115200 is default In case of Ethernet enter IP address of OMM 1000 and port number 3000 is default port number of OMM 1000 Click save button and close Set Config window then click Connect button on PC program of OMM 1000 to st...

Страница 21: ...to save it 4 1 4 Control Lock Mode It locks and unlocks the controls such as Web Data control RS 232 TCP IP and UDP and key button input Click Apply button to save it 4 1 5 Network It changes network information of OMM 1000 Click Apply button to save it 4 2 EDID setup OMM 1000 offers 3 types of EDID setting for easy installation with various displays in the market To set the EDID option for each i...

Страница 22: ...ys and copies it in input port Select output channel first and click input channels And click Apply button to save it There is User s Edit mode but it is used to modify existing EDID to make new EDID working with specific systems It is not recommended for general user For further information please contact techsupp opticis com 4 3 Operation And all of setting parameters will be shown on the right ...

Страница 23: ...own in Fig 4 5 To connect one input to all output click All Link button and click desired input Then all of output will be connected to it To disconnect all outputs click Link Clear button 4 3 2 Input channel status Green LEDs above input channel number such as CH05 and CH10 are signal detection from source It means only CH05 and CH10 are connected with video sources If the green LED lit ON user c...

Страница 24: ...er optic output card SDVI 1F0 and Slot 2 is electrical DVI output card SDVI 4EO 4 3 4 Multi viewer The most outstanding feature of OMM 1000 is embedded multi viewer card QDVI O Multi viewer card QDVI O can choose 4 inputs among 16 inputs of OMM 1000 and configure and output these input signals with 7 different layouts Fig 4 6 Layouts of Multi viewer 1 st layout Select 1 st input of QDVI O and outp...

Страница 25: ...e 1 Changing the output resolution and layout of multi viewer card QDVI O can be done by PC program and command input and key button operation 2 To change position of window in layout 5 6 and 7 user must change the order of input to QDVI O For example If the QDVI O is in output slot 2 to change window position of layout 5 as shown in Fig 4 8 user must change input output connection Fig 4 8 Changin...

Страница 26: ...side 3 Scale down error will happen when the number of scale down vertical pixels are less than 1 5 Progressive input case or 1 4 Interlaced input case of original input vertical pixels For example in case of layout 6 if you use input resolution 1280x1024 and set the output resolution of QDVI O at 800x600 the number of vertical pixels of 1 st 2 nd and 3 rd inputs will be fitted into one third of o...

Страница 27: ...o control OMM 1000 please confirm that Network setting of OMM 1000 and Ethernet connection of the PC Refer to Chap 2 and Chap 3 Launch the web browser and enter the IP address of current OMM 1000 into the URL address line For example if the IP address of OMM 1000 is set as 192 168 001 117 jut type 192 168 1 117 Fig 5 1 Web control panel Fig 5 1 shows structure of Web control panel It controls inpu...

Страница 28: ...e is Command Delimiter Data Delimiter or or _ Data End Table 6 1 shows all commands and its brief descriptions Command Description LINK Input and Output connection IN Input signal status request OUT Output signal status request NET Network information request NETGW Gateway address setting NETSN Subnet mask address setting NETIP IP address setting NETPA MAC address setting NETPT UDP port number set...

Страница 29: ...tatus of OMM 1000 Command Description and reply LINK 01 10 Makes input 1 connected to output 10 Reply LINK 01 10 LINK 1 03 04 7 Makes input 1 connected to output 3 and 4 to 7 Reply LINK 01 03 04 07 LINK 05 Makes input 5 connected to all outputs Reply LINK 05 LINK 00 Makes all connections disconnected Reply LINK 00 LINK 00 06 Makes output 6 disconnected Reply LINK 00 06 Link Requests current inputs...

Страница 30: ...ata ranges from 0 to 65535 NETPT 3000 NET Requests current network setting Reply NETGW 192 168 001 001 NETIP 192 168 001 118 NETSN 255 255 255 000 NETPA AA BB CC DD EE FF NETPT 3000 Table 6 4 Network setting command examples 6 2 4 Video generator setting It changes resolution and pattern of video generator It requests current video generator setting Table 6 5 describes the resolutions and patterns...

Страница 31: ...G 3 Sets video generator pattern by data 3 Reply VIDIMG VCOLORBAR10SMOVE VID Requests current video generator resolution and pattern Reply VID 04_03 it means data 4 resolution and data 3 pattern Table 6 6 Video generator command examples 6 2 5 Monitor output port setting It makes input to connected to monitor output port It requests current input port that connected to monitor output port Command ...

Страница 32: ... EDID 02AUTO EDID 08AUTO EDID 09AUTO EDID OUT3_5 Output copy mode Copies EDID information of output 3 display and stores it in input port 5 Reply EDID 03OUT EDID Requests current EDID setting for all inputs Reply EDID 01OUT 02AUTO03OUT 16EDF Table 6 8 Monitor output setting command examples 6 2 7 Baud rate setting for RS 232 It sets RS 232 baud rate OMM 1000 supports 9600 19200 38400 57600 115200b...

Страница 33: ...om side 8 9 1920x1080p 60Hz Table 6 10 Supporting resolutions and layouts of QDVI O The first numeric data in command line represents slot number of output bay of OMM 1000 where QDVI O is inserted Command Description and reply QUADRES 3_9 Sets output resolution of QDVI O at 1920x1080P In this case QDVI O is inserted in 3 rd slot of output bay Reply QUADRES 03_09 QUADLAY 1_5 Sets layout of QDVI O a...

Страница 34: ...d HDMI 4EO Table 6 12 Card types and its data The first numeric data in reply represents the order row of slot and second and third data represents type of input and output cards Command Description and reply SLOT Requests current cards type in input and output bay OMM 1000 has 4 rows of input and output slots If the input output cards are configured as below 1 st row Single DVI input card 1 Fiber...

Страница 35: ...KUL Table 6 15 Control lock command examples 6 2 11Preset Control Commend It saves routings under a preset number It requests current Preset mode setting Command Description and reply PRE SAVE Preset Number Requests to save the current routings under the preset number selected Reply PRE SAVE Preset Number _ link state Example Send PRE SAVE01 Reply PRE SAVE01_00 01 00 02 00 03 00 04 00 16 04 04 ind...

Страница 36: ...are update 1 Please install under Windows XP OS Note Megaboot exe can t be installed under Windows 7 and Vista OS 2 Click Open of File to be programmed in the Flash to select directory and file hex Format to be uploaded ...

Страница 37: ...1 to D Sub 9Pin cable RS 232 cable 4 Select Comm port to select communication port of PC for RS 232 communication with OMM 1000 5 To enable Comm port Click when it shown as Serial Port Enable 6 Power On of OMM 1000 7 Then the firmware will be uploaded and its status will be shown in the message box shown as below ...

Страница 38: ...38 8 After 3 4 minutes Application Code Runing message will be shown Then the firmware upload is completed 9 Please close a megabox exe program and reboot OMM 1000 to run it under new firmware ...

Страница 39: ...tput connection configuration you want The display is not capable of handling graphic resolution Check the compatibility of EDID in the EEPROM and attached displays When a single Input is routed to multiple outputs lower resolution EDID should be selected EX Input 1 Output 1 UXGA Output 2 SXGA If EEPROM 1 store the display 1 EDID UXGA the display 2 SXGA will not work due to resolution limit The so...

Страница 40: ...ed 1 sec If No format searching by Display Front Key LED key Use of long term reliability prepared product In Output card Spec Size 440 x 380 x 178mm WDH 4U 19 Section Model name In Output port Single DVI input SDVI 4EI 4 x DVI D receptacle Weight 11Kg net weight for single power Single DVI output SDVI 4EO 4 x DVI D receptacle Dual DVI input DDVI 2EI 2 x DVI D receptacle Dual DVI output DDVI 2EO 2...

Страница 41: ...resolution SDI card SDI card 480i 720p 60 576i 720p 23 98 720p 30 720p 24 720p 50 720p 25 720p 59 94 720p 29 97 720p 60 1035i 720p 60 1080i 1080sf 1080p 60 1080p 23 98 1080p 30 1080p 60 1080p 24 1080p 50 1080p 25 1080p 59 94 1080p 29 97 1080p 60 SDI card HDMI DVI Fiber card 480i SXGA 1280x1024 576i 720p 23 98 720p 30 720p 60 720p 24 720p 50 720p 25 720p 59 94 720p 29 97 720p 60 1035i 720p 60 1080i...

Страница 42: ...VI 4EI Pass Pass Pass Pass Pass SDVI 1FI Pass Pass Pass Pass Pass HDMI 4EI N D Pass Pass Pass Pass SDI 4EI N D Pass Pass Pass Pass 9 5Compatibility between DisplayPort In Output cards and another In Output cards Input card Output card Resolution DP1 4EI DP1 4EO Up to WQXGA 2560x1600 at 60Hz Not support Deep color DP1 4EO SDVI 1FO Up to WQXGA 2560x1600 at 60Hz SDVI 4EO HDMI 4EO SDI 4EO DDVI 2EO Inp...

Страница 43: ...ed product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation unde...

Страница 44: ...tes for disposal Chapter 11 Safety Instructions WARNING Do not touch signal input signal output of other connectors and the patient simultaneously WARNING Do not connect any accessory except provided by Opticis Any damage caused other power adapters or accessories will not be taken any responsibility by Opticis Warning for Medical usage WARNING External equipment intended for connection to signal ...

Страница 45: ...MA 5 15 style plug labeled for 125 volts AC with UL and C UL approvals If the power source is a 240 V AC supply use the tandem T blade type attachment plug with ground conductor power cord that meets the respective European country s safety regulations The hospital grade plug for medical products intended for use in Denmark has DEMKO approval and is rated 13 amps at 250Vac This plug is recommended...

Страница 46: ...t your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com Cleaning Turn off the power Remove all of the electrical and optical fiber from the Modular matrix chassis OMM 1000 Separate each input output card from the body Put the cards on the safety place and keep it carefully Clean with dry cloth inside of the body after each card is...

Страница 47: ...ich can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service t...

Страница 48: ...f Old Electrical Electronic Equipment caution Refer to instruction use FCC certificate Symbol Remark MEDICAL EQUIPMENT WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601 1 CAN CSA C22 2 NO 601 1 5BF0 Box Symbol Symbol Remark Loading direction Fragile caution Wet caution RoHS certificate ...

Страница 49: ...contact techsupp opticis com Opticis Locations HQ 16Fl Kins Tower 8 Seongnam daero 331 beon gil Bundang gu Seongnam si Gyeonggi o 463 844 Rep of KOREA Tel 82 31 719 8033 Fax 82 31 719 8032 Factory 501 Byoksan Technopia 560 Dunchon daero Jungwon gu Seongnam si Gyeonggi do 462 716 Rep of KOREA Tel 82 31 737 8033 Fax 82 31 737 8039 ...