Chapter-2
Before Using
NLV-5201 User's Manual
14
1st
Ultra High Resolution model (UD) Depth of Field
2.5.3
* The depth of field is the typical value measured by tilting the test chart 15° from the optical axis. (25C°)
* Refer to 11.2.2 Technical Specifications Ultra High Resolution model (UD) Reading Depth of Field for specified
value.
0
0
25
50
[Unit: mm ]
Code 39
EAN/UPC
QR Code
Data Matrix
0.076mm(3mil)
28
65
0.127mm(5mil)
23
82
0.254(10mil)
53
108
0.33mm(13mil)
50
0.084mm(3.3mil)
33
55
0.381mm(15mil)
22
109
25
50
75
100
25
50
120
0.084mm(3.3mil)
35
55
0.254mm(10mil)
22
86