background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Quick Start Guide 

 
 
 
 
 

OSD2258 

10-PORT REDUNDANT RING 

GIGABIT ETHERNET SWITCH 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание OSD2258

Страница 1: ...Quick Start Guide OSD2258 10 PORT REDUNDANT RING GIGABIT ETHERNET SWITCH...

Страница 2: ......

Страница 3: ...P CONFIGURATION 11 10 GUI OVERVIEW 12 10 1 DEFAULT SETTING 12 10 2 LOG INTO THE SWITCH 12 10 3 IP CONFIGURATION 13 10 4 VLAN 13 11 RESET TO FACTORY DEFAULT 13 12 WARRANTY 14 12 1 WARRANTY PERIOD 14 12...

Страница 4: ...ducts are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area All laser apertures should be covered by protective covers wh...

Страница 5: ...2 OSD2258 QUICK START GUIDE PAGE 5 3 OSD2258 FRONT AND REAR PANELS 3 1 FRONT PANEL FIGURE 1 FRONT PANEL Power LED Ring LED Activity LED x 8 Link LED x 10 Ports 1 4 RJ45 Copper Ports Ports 5 8 RJ45 Cop...

Страница 6: ...58 QUICK START GUIDE PAGE 6 3 2 TOP PANEL FIGURE 2 TOP PANEL 3 3 BOTTOM PANEL FIGURE 3 BOTTOM PANEL Power 1 LED Power 2 LED Dual Redundant Power Input Alarm Output 1 2 8 Way Configuration Switches Min...

Страница 7: ...10 to 36VDC or 22 to 28VAC 10VA 5 Alarm Connections The OSD2258 has two monitoring alarm outputs 1 Ring to Bus Alarm and 2 Temperature Alarm The alarm connections and conditions for alarm outputs are...

Страница 8: ...MBER DESCRIPTION FUNCTION SWITCH POSITION 1 GUI Mode Enable WebGUI On Disable WebGUI Off 2 Not Used On Off 3 Not Used On Off 4 High PoE 60W per port On Auto Mode Off 5 Not Used On Off 6 Ring Non Ring...

Страница 9: ...Link Established Blink SFP Link OK Activity 8 Fitting SFP Connectors Care should be taken when inserting removing the SFP connectors from the SFP port as SFP modules are Electrostatic ES sensitive an...

Страница 10: ...SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 10 9 CLI OVERVIEW 9 1 CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers is needed to be installed on the PC before connecting the...

Страница 11: ...ole Port on UUT to PC with USB cable Type A to Type B 2 Using HyperTerminal to set up the following parameters Baud Rate 57600 Data Bits 8 Parity None Stop Bits 1 Flow Control None 3 Check the link by...

Страница 12: ...2 LOG INTO THE SWITCH Connect a switch port to a PC Change the PC s network IP address to connect to the switch i e 192 168 0 2 In a web browser enter the URL default 192 168 0 99 The GUI should now h...

Страница 13: ...Click Save button to save changes Earlier versions will have the VLAN function permanently enabled 11 Reset to Factory Default Changes made to settings IP VLAN etc through the GUI are saved when in de...

Страница 14: ...ve for all repairs 12 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 12 2 2 OUT OF WARRANTY REPAIRS OSD reserves th...

Страница 15: ...OPTICAL SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 15...

Страница 16: ...y Ltd 7 1 Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY...

Страница 17: ...OPTICAL SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 17 Printed in Australia...

Отзывы: