OPERATOR MANUAL
OSD2244V SERIES
5-PORT REDUNDANT RING
GIGABIT ETHERNET SWITCH
Страница 1: ...OPERATOR MANUAL OSD2244V SERIES 5 PORT REDUNDANT RING GIGABIT ETHERNET SWITCH...
Страница 2: ......
Страница 3: ...8 2 4 1 INSTALLING FLIP 18 2 4 2 INSTALLING USB DRIVER 20 2 4 3 UPGRADE FIRMWARE 22 2 4 4 INSTALLATION CHECK 23 2 5 COMMAND LINE INTERFACE 24 2 5 1 TERMINAL EMULATION SETUP 24 2 5 2 COMMAND LINE FUNCT...
Страница 4: ...TOPOLOGY CHECK 26 FIGURE 19 TOPOLOGY CHECK 27 FIGURE 20 NODE CHECK 28 FIGURE 21 LOCAL NODE CHECK 29 FIGURE 22 FLOAT BACKUP ENABLED 1 30 FIGURE 23 RING TOPOLOGY 30 FIGURE 24 FLOAT BACKUP ENABLED 2 31...
Страница 5: ...fiber operation A major benefit of the OSD2244V is its reliable and consistent performance over the 20 C to 75 C temperature range that allows it to be used in uncontrolled environments such as roadsi...
Страница 6: ...CAL SYSTEMS DESIGN DOC ID 10111103 OSD2244V OPERATOR MANUAL PAGE 6 1 2 TYPICAL CONFIGURATION Figure 1 below indicates a possible set up for an OSD2244V system FIGURE 1 OSD2244V TYPICAL RING CONFIGURAT...
Страница 7: ...Transmit Optical Power 10dBm to 4dBm 5dBm and 2dBm 1310nm and 1550nm are optional Receiver Sensitivity 21dBm Standard Optical Link Budget 11dB 800m on multimode fiber 1310nm Fiber bandwidth limited 2...
Страница 8: ...n be either copper or fiber on the front panel The rear panel consists of a 6 way terminal block power connector 4 Way DIP switch Type A USB connector and a Type B USB connector Each section will be d...
Страница 9: ...ct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard C...
Страница 10: ...to be mounted on an even surface and to be secured by means of M4 or smaller screws The OSD2244V card version is designed to be inserted into a chassis and secured by means of captivated screws a Modu...
Страница 11: ...ation Power should be connected to the power socket located at the back of the case as indicated in Table 2 TABLE 2 DC OR AC POWER CONNECTION External Power Pin Specification Pin 1 and or 5 8VDC to 35...
Страница 12: ...or further CLI information FIGURE 6 USB TYPE B CLI PORT To operate and control the OSD2244V using the CLI an OSD2244V driver will be required to be installed onto the PC being used The driver can be f...
Страница 13: ...bps 10Mbps Full Duplex Half Duplex On On Power On Power Off On Ring Bus Master Ring Bus Slave On No Activity Activity No Link 1Gbps 100Mbps 10Mbps Forward Backup On No Activity Activity No Link 1Gbps...
Страница 14: ...TCH TABLE 4 OSD2244V 4 WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION FUNCTION SWITCH POSITION 1 Port 5 Fiber Speed 1000Mbps 100Mbps OFF ON 2 Port 4 Fiber Speed 1000Mbps 100Mbps OFF ON 3 Port 3 Fib...
Страница 15: ...SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Rem...
Страница 16: ...ONS For RJ45 connection use Category 5 CAT5 or higher Length should be no more than 100 meters For singlemode fiber connections fiber used must be 9 125 m singlemode fiber For multimode fiber connecti...
Страница 17: ...4V has it s own unique MAC address The MAC address of each unit is labelled on the OSD2244V When the unit is connected in a ring configuration one of the OSD2244V units will be allocated the ring mast...
Страница 18: ...ing toggle switch 4 to the off position and power the unit on again FIGURE 15 OSD2244V USB CONNECTOR Upgrading the OSD2244V latest firmware consists of three steps 1 Install FLIP Flexible In System Pr...
Страница 19: ...OPTICAL SYSTEMS DESIGN DOC ID 10111103 OSD2244V OPERATOR MANUAL PAGE 19 Disable Create desktop shortcut and Show readme and click Finish...
Страница 20: ...USB DRIVER Toggle switch 4 to on position see Figure 10 before unit is powered on Connect USB cable between target unit and PC with FLIP installed Power the OSD2244V unit and follow steps outlined bel...
Страница 21: ...OPTICAL SYSTEMS DESIGN DOC ID 10111103 OSD2244V OPERATOR MANUAL PAGE 21...
Страница 22: ...44V OPERATOR MANUAL PAGE 22 2 DRIVER FOR WINDOWS 7 64bit For 64bit operating systems use directory named win7 driver on CD as destination location for driver file 2 4 3 UPGRADE FIRMWARE 1 Copy firmwar...
Страница 23: ...p device at32uc3a1512 hardware usb operation erase f memory flash blankcheck loadbuffer c osd firmware 60001701 hex program verify start reset 0 NOTE 60001701 hex used in the command line above is jus...
Страница 24: ...riate cable as specified in section 2 2 5 Using a terminal emulation program such as Hyperterminal a number of command lines specific to the OSD2244V can be implemented to check link node status ring...
Страница 25: ...e unit is switched on while plugging in the USB cable however the command lines are functional FIGURE 17 INITIAL COMMAND LINE SCREEN The following table outlines the user available command line comman...
Страница 26: ...Init as there is only one unit NODE_ROLE MASTER Displays whether the unit is either the Master or Slave on the ring bus in this case only one unit is connected thus displaying master PORT4 U_port Indi...
Страница 27: ...is either the Master or Slave on the ring bus Master is determined by the lowest MAC address PORT4 U_port Indicates the function of port 4 and its relation to the ring bus There are four possibilitie...
Страница 28: ...e is plugged into This enables the user to perform a node check on any OSD2244V unit from one location on the ring bus network The Node Check command requires the MAC address number for the node being...
Страница 29: ...PAGE 29 LOCAL NODE CHECK lnc Command Line FIGURE 21 LOCAL NODE CHECK This command line displays the running status of the local node that the USB cable is plugged into The information provided is the...
Страница 30: ...e ring bus having Float Backup enabled SETTING_RESULT OK Displays the Float Backup enable has been successfully implemented local This points to the unit that the USB cable is plugged into on the ring...
Страница 31: ...node 1 will communicate with node 3 via node 2 and node 4 FIGURE 24 FLOAT BACKUP ENABLED 2 When the float backup is in enabled mode if the broken or disconnected branch is re established the backup br...
Страница 32: ...splays all the units connected to the ring bus having Float Backup disabled SETTING_RESULT OK Displays the Float Backup disable has been successfully implemented local This points to the unit that the...
Страница 33: ...P DISABLED 2 When the float backup is in disabled mode if the broken or disconnected branch is re established the backup branch will again be the furthest link from the smallest MAC addressed unit as...
Страница 34: ...ssary traffic flow between devices A regular LAN ie no VLAN setup broadcasts packets of data to entire network devices regardless of whether they need it or not causing congestion to the entire networ...
Страница 35: ...ongs to and can forward the frame to the corresponding VLAN access ports FIGURE 30 FRAME TAG The OSD2244V frame tag consists of 16 bit Tag Protocol Identifier TPID which is inserted into the header of...
Страница 36: ...rt Default PRI priority is a parameter assigned to every Non Ring Port via CLI and stored in a non volatile memory within the OSD2244V It may be used as the priority level for the ingressing frame dep...
Страница 37: ...either a Fixed Priority or Weighted Fair queuing modes The modes can be selected via CLI Table 6 outlines the details For Fixed Priority mode all top priority frames egress for a port until that prior...
Страница 38: ...the frame does not belong to any VLAN which carries priority information only and is referred to as Priority Only Frame A Priority Only Frame is treated as a tagged frame The OSD2244V supports up to 6...
Страница 39: ...of every VLAN entry and every ingressing frame is allowed to exit them By using a PC and CLI an entry of VLAN can be added or deleted from the VLAN Table Once 802 1Q VLAN is enabled on OSD2244V a VLA...
Страница 40: ...to perform configurations on each OSD2244Vunit prior to connecting any devices and optical fiber It is also equally important to understand the topology and network the user is attempting to achieve A...
Страница 41: ...e restored back to set values at power on 3 3 2 CONFIGURATION CHECK Two CLI commands are available for checking the VLAN settings VLAN MODE AND SCHEDULING MODE CHECK vmc Command Line FIGURE 35 VLAN MO...
Страница 42: ...e number of VLAN identifications assigned to the OSD2244V There are a maximum of 255 VID numbers possible per OSD2244V VID Indicates the assigned VLAN ID 001 to 225 VIDs are valid Note there cannot be...
Страница 43: ...i_Mode Priority Mode of OSD2244V There are two possibilities 1 VID_Based 2 Normal Def_VID Pri Port Default VID indicates the port VID Values 0 254 are valid Port Default Priority indicates the priorit...
Страница 44: ...is Normal 802 1Q VLAN is disabled Note to enable 802 1Q VLAN type vps on the CLI See section 3 4 for detailed information When enabling the 802 1Q VLAN the initial configurations are as shown Figure...
Страница 45: ...onnections to PC Refer to section 2 5 Command Line Interface to enable CLI configurations It is highly suggested to understand the topology and network the user is attempting to achieve before configu...
Страница 46: ...et Egress Mode to Tagged or Untagged for non ring ports vlan_pri_mode_set vpms vpms p1_mode p2_mode p3_mode Enable or disable VID Based Priority for non ring ports vlan_pri_scheduling_mode vpsm vpsm m...
Страница 47: ...CLI Command CLI Syntax Parameters Factory Default Example vpdv vpdv p1 vid p2 vid p3 vid 0 254 1 vpdv 101 102 103 Note The parameter value can by any value between 0 254 Duplicate values on different...
Страница 48: ...efault Example vvos vvos p1 bit p2 bit p3 bit 0 No override 1 Override 1 vvos 0 1 1 VLAN PORT EGRESS MODE Set Egress Mode to Tagged or Untagged for non ring ports CLI Command CLI Syntax Parameters Fac...
Страница 49: ...CLI Command CLI Syntax Parameters Factory Default Example vduf vduf p1 bit p2 bit p3 bit 0 Not Discard 1 Discard 0 vduf 1 0 0 VLAN PORT SECURE SET Set Security Level to High or Low for non ring ports...
Страница 50: ...1 SCENARIO 1 In this scenario four OSD2244Vs connected together with two third party managed switches to build IEEE802 1Q VLANs There are four VLANs in this network and the QoS priority is required t...
Страница 51: ...1 20 1 vpem 0 0 1 vvos 1 1 0 veta 10 1 0 0 1 veta 20 2 0 1 1 veta 40 4 0 0 1 vpms 1 1 1 vms 1 vpdv 40 1 30 vpem 0 0 0 vvos 1 1 1 veta 30 3 0 0 1 veta 40 4 1 0 0 vpms 1 1 1 Notes Configurations for th...
Страница 52: ...OPTICAL SYSTEMS DESIGN DOC ID 10111101 OSD2244V OPERATOR MANUAL PAGE 52...
Страница 53: ...ongs to VLAN30 OSD2244V No1 is connected to an OSD2144 which is an unmanaged ethernet switch Main monitoring computer which is connected to OSD2144 can get images from all three IP Cameras simultaneou...
Страница 54: ...10 0 1 0 0 veta 20 0 0 1 0 veta 30 0 0 0 1 Same as No1 Same as No1 Same as No1 Notes As a replacement a third party ethernet switch could be used for this scenario But user should be sure that its por...
Страница 55: ...e damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performin...
Страница 56: ...tive for all repairs 5 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 5 2 2 OUT OF WARRANTY REPAIRS OSD reserves th...
Страница 57: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...