background image

 

 

 

 
 
 
 
 
 
 
 
 

 

In UPS

 

 

Hybrid Inverter series

 

 

 
 
 

 

User’s Manual 

Sine Wave Output 

SP4000-AVR 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.opti-solar.com

 

Содержание SP4000-AVR

Страница 1: ...Inverter UPS Hybrid Inverter series User s Manual Sine Wave Output SP4000 AVR www opti solar com...

Страница 2: ...e tools with insulated handles To increase the balance of the inverter the additional stabilizer is to be mounted at the bottom side This unit should be installed by qualified personnel The equipment...

Страница 3: ...near liquids or in an excessively damp environment Do not let foreign objects penetrate the inverter Never block the ventilation grates of the inverter Never expose the inverter to direct sunlight or...

Страница 4: ...ated warning should be observed CAUTION REFER TO USER S MANUAL Refer to this user s manual for additional information such as important operation and maintenance information SAFETY GROUNDING TERMINAL...

Страница 5: ...2 3 Description of the Rear panel 8 3 INSTALLATION 9 4 OPERATION 10 5 INDICATION AND CONTROL 13 5 1 LED Display 13 5 2 LCD Display 13 5 3 Audible alarms 15 5 4 Auto Self test Function 15 5 5 Remote C...

Страница 6: ...condition With outstanding performance and reliability the unique benefits of the inverter include the following Pure sine wave output Microprocessor based design with true Line Interactive structure...

Страница 7: ...same control method Please refer to the following example LEDs of battery voltage level and load level LED of operation status Control Button 2 2 LCD display models The following is one example of LCD...

Страница 8: ...utput Terminal and or Outlet s NEMA or IEC 4 RS 232 Interface port for applications with optional monitoring software 5 DIP Switch 6 RJ 45 Interface for a Remote LCD display Optional 7 Battery connect...

Страница 9: ...specifications 3 3 Connect the DC input power cord to the battery bank Mind the battery bank s voltage and the polarity The inverter must be as close as possible to the battery bank to avoid the volt...

Страница 10: ...the power 4 4 Auto Bypass When the auto bypass function is enabled the Inverter will transfer to by pass mode any time when the inverter is turned OFF It prevents the important connected equipment fr...

Страница 11: ...ars on the LCD screen Then push two selection buttons at the same time to change to the next setting or leave the LCD blinking for 30 seconds to finish setting the Inverter and to return to the normal...

Страница 12: ...to 1 of full load The inverter will turn OFF the power automatically after a blackout occurs if the load level is less than 1 of the rated full load Push the selection button for 2 seconds at least t...

Страница 13: ...e lighted in normal mode the battery is fully charged The load level LEDs show the percentage of added load in relation to the Inverter s rated capacity When all five LEDs are lighted the Inverter is...

Страница 14: ...This symbol will show up in the following situations 1 A Turn ON Turn OFF schedule has been set using the monitoring software Refer to paragraph 5 5 and the Readme file or Help function of the monitor...

Страница 15: ...a sound alarm When in on battery mode the Utility Failure alarm can be silenced by pushing the Silence button However the Battery Low warning cannot be muted Basic Indication Table STATUS ALARM REMAR...

Страница 16: ...ted please unplug the AC input power cord and push the ON OFF button for at least 15 seconds This will reset the Inverter 5 7 DIP Switch Settings Two options one is for setting the charger parameters...

Страница 17: ...6 RS 232 data Tx out Pin 7 Common of Pin 6 and Pin 9 Pin 9 RS 232 data Rx In 6 2 The definition and setup for DB9 optional is shown as follows Pin 2 AC Power Failure Pin 4 Common GND of Pin 2 Pin 5 P...

Страница 18: ...vide expected on battery run time 1 Excessive load is connected to Inverter s outlets 2 Battery is weak and cannot provide enough capacity Do not operate the Inverter leave the Inverter plugged in for...

Страница 19: ...sfer Time Blackout 3ms typical Over and under voltages 1ms typical Battery mode to Normal mode 1ms typical Overcurrent Protection Overload alarm level 100 120 Overload shutdown level 120 190 Adjustabl...

Страница 20: ...rt RJ45 Surge protection DB9 SNMP external type Control Panel LCD Audible Alarms Alarm on battery Low battery Battery over voltage Alarm on abnormal operation Overload Short circuit Overheat Green Mod...