CONTROLLER
STANLEY
TB3
TB1
TB4
TB2
TB5
OMD-101
OA-605
OA-605
Door loop
OC-905C(S)
Master: Encoder1
(Dipswitch4:OFF)
See section7.
Set dipswitch as shown below.
Dipswitch settings of OMD-101
4
3
1
2
ON
4
5
6
7
8
3
1
2
ON
Dipswitch1
If setting is ON, after 10 sec. of "Dead Lock" , OC-905C(S) emits Creep Signal.
Dipswitch3
ON : knowing act application, OFF : fully automatic application.
Dipswitch4
ON : "Slave (Encoder2) ", OFF : "Master(Encoder1) ".
When connected a single door (one door), set to OFF.
When connected a double door (two doors), select ON or OFF respectively.
NOTE
See ELITE ST specification manual for each dipswitch definitions.
Dipswitch settings of OC-905C(S)
Set dipswitch as shown below.
NOTE
See ELITE ST specification manual for each dipswitch definitions.
OMD-101
OC-905C(S)
Placement the Sensor heads
MANUFACTURER'S STATEMENT
WARNING
CAUTION
NOTE
Disregard of warning may cause the improper operation causing death or serious injury of a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause the improper operation causing injury of a person or damage to objects.
This Installation manual will help identify and resolve some of the most common installation issues. This guide will also
verify that all Dipswitch settings and Area Depth adjustments are properly set. If after verifying all nine steps proper
operation has not been achieved, please contact our Technical Support Team at (800) 877-6656.
ELITE ST
5917330 MAY 2010
Installation manual
Read this manual carefully before install. Failure to read this manual may cause improper operation and may result in
serious injury or death of a person.The meanings of the symbols are as follows.
Please study the following first and then read the contents of this manual.
Mounting templates should be aligned with the pivot edge of the door .
Template Labeled "Left Hinge Side".
Template Labeled "Right Hinge Side".
NOTE
Edge of the template aligned the hinge of door.
Make sure to attach the both templates (Swing Side , Approach Side) on the same horizontal level.
Fix the Sensor heads
OMD-101 on MC521 controller
The procedure for OMD-101 is same for that of SENTREX MICRO BOARD
WARNING
Turn "Power Switch" on MC521 controller OFF.
1. Remove one of hexagon standoffs from MC521controller.
2. Tight the longer hexagon standoff (ELITE_ST Accessories) .
3. Connect OMD-101 to Sentrex (J401) connector on MC521Controller.
4. Fix the board with the shorter hexagon standoff (ELITE_ST Accessories) .
Wiring
Wiring the cable as shown below.
1. Drill mounting holes and a wiring hole according to the mounting template.
NOTE
Fix the door loop
1. Knockout the side of a cover closer to OA-605.
2. Connect the door loop cable to OA-605.
3. Fix the door loop cover.
Connect pass thru
the communication cable to
both OA-605 sensor heads.
For concealed wiring
For double door connection
Feed the connector.
Fix the cover.
For surface wiring.
Knockout the cover.
Supplied flexible wire
shroud is cut to fit on
site.
PUSH
PLATE
For knowing act application, connect purple
wires to push plate (or to Activation sensor).
See section7.
NOTE
On pairs, purple wires from OC-905C(S)s connect
in parallel. Be sure to observe po to +, - to -).
Do not connect purple wires to MC-521.
OA-605
OA-605
Door loop
OC-905C(S)
Slave: Encoder2
(Dipswitch4:ON)
See section7.
Power Supply (+)
Communication TXD
Communication RXD
Power Supply (-)
: Red
: Green
: White
: Black
TB1 PIN1
TB1 PIN2
TB1 PIN3
TB1 PIN4
OC-905C(S)
MC521
CONTROLLER
STANLEY
TB3
TB1
TB4
TB2
TB5
2. Remove the mounting template.
3. Fix the OA-605 sensor heads.
How to remove the cover
Insert the flat head screw driver and push it down.
Hold the top and remove the cover.
Activation
sensor
Make a hole on one side. Door loop will be install on
one side only
.
All activation devices must be connected to Purple wires.
OC-905C(S)
Fix the cover.
Connect cable
Communication cable
0.2m (8")
Communication cable 2.2m (7'3")
Communication cable 2.2m (7'3")
Communication cable
0.2m (8")
Wiring cable 0.6m (2')
Wiring cable 0.6m (2')
Red arrow : Mandatory
Black arrow : See the setting below
Gray arrow : N/A
Black arrow : See the setting below
Gray arrow : N/A
1
2
3
4
5
6
7
Daughter board
OMD-101