background image

(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
(5) Depth angle adjustment screw
(6) Radar sensitivity potentiometer
(7) Dipswitches 
(8) Detection window
(9) Area adjustment tool

Knockout

OAM-DUAL II

ENGLISH

5928750  NOV 2019

Manufacturer's statement

Read this operation manual carefully before use to ensure proper operation of this product.

Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.

The meanings of the symbols are as follows.

Failure to follow the instructions that accompany this indication and improper handling

may result in serious injury or death.

WARNING

Failure to follow the instructions that accompany this indication and improper handling

may result in injury and/or damage to property.

CAUTION

Pay special attention to sections with this symbol.

NOTE

1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic

    sliding door. Do not use for any other applications. 

2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.

3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment

    connected to the product.

4. Only use the product as specified in the operation manual provided.

5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country

    in which the product is installed.

6. Before leaving the installation site make sure that the product is operating properly and instruct the

    building owner/operator on proper operation of the door and the product.

7. The product settings can only be changed by an installer or service engineer.

    When changed, the changed settings and the date shall be registered in the maintenance logbook

    accompanying the door.

NOTE

Do not wash, disassemble,

rebuild or repair the sensor,

otherwise it may cause electric

shock or breakdown of the

equipment. 

Danger of electric shock

WARNING

The following conditions are not suitable for sensor installation.

Fog,

Exhaust

Wet

Vibration

Objects

Reflection

Specifications

Model

Cover color

Mounting height

Detection area

Detection method

Transmitter frequency

Transmitter radiated power

Depth angle adjustment

Power supply

Power consumption

Operation indicator

Output hold time

Response time

: OAM-DUAL II

: Black

: 2.0 to 3.5 m (6'7" to 11'6")

: See 

Detection area

: Active infrared reflection (*1)

  Microwave Doppler effect

: 24.125 GHz

: < 20 dBm

: AIR area -6 to +6°

  Radar area +25 to +45°

: 12 to 24 VAC ±10 % (50/60 Hz)

  12 to 30 VDC ±10 %

: < 2.5 W (< 4 VA at AC)

: See 

Operation indicator table

: < 1.0 s

: < 0.3 s

Operating temperature

Operating humidity

Noise level

Activation output

Safety output

IP rate

Weight

Accessories

: -20 to +55°C (-4 to 131°F)

: < 80 % (non-condensing)

: < 70 dBA

: Form C relay 50 V 0.3 A Max.

  (Resistance load)

: Form C relay 50 V 0.3 A Max.

  (Resistance load)

: IP54

: 270 g (9.5 oz)

: 1 Operation manual

  2 Mounting screws

  1 Mounting template

  1 Area adjustment tool

  1 Cable 3 m (9'10") 

  1 Narrow lens

1 s

1 s

Signal saturation

Sensitivity too low(or Sensor failure)

Slow Green blinking

Fast Green blinking

Operation indicator table

Warm-up

Stand-by (Installation mode)

Status

Yellow blinking

Yellow

Operation indicator color

Stand-by (Operation mode)

2nd row detection

BLUEZONE (Lookback) detection (*2)

3rd row detection

Radar detection

Green

Orange

Red

 

Red blinking

Blue

The specifications herein are subject to change without prior notice due to improvements.

*1 : Active infrared reflection has a presence detection function.

*2 : See 

BLUEZONE

.

NOTE

When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is

activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".

Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.

BLUEZONE (Lookback) area

BLUEZONE

(Lookback)

2nd row

3rd row

BLUEZONE

(Lookback)

2nd row

3rd row

(1)

(4)

(5)

(8)

(6)

(9)

(3)

(2)

(7)

Outer dimensions and part names

AIR 

Mounting height : 2.2 m (7'3")

Angle adjustment : +6°

Sensitivity : Middle

: Emitting spots

: Detection area

: Emitting spots

  (can be eliminated)

Detection area

A

C

B

BLUEZONE(Lookback)

2nd row

3rd row

D E

F

[m(feet,inch)]

Mounting

surface

1.0

(3′3")

2.0

(6′7")

2.0

(6′7")

2.0

(6′7")

1.0

(3′3")

1.0

(3′3")

0

Radar

Mounting height : 2.2 m (7'3")

Vertical adjustment : +35°

Sensitivity : High

Speed of detection object

                                : 50 mm/s

: Detection area

  (Wide area)
: Detection area

  (Narrow area)

Installation

The actual detection area may become smaller depending on the ambient light, the color/material of

the object or the floor as well as the entry speed of the object.

The sensor may not be activated when the entering speed of the object or a person is slower than 

50 mm/s or faster than 1500 mm/s.

AIR emitting area

[m(feet,inch)]

The chart shows the values at depth angle +6°.

NOTE

Do not use the sensor without the cover. When using the cable knockout,

install the sensor indoors or use the rain cover (Separately available)

otherwise electric shock or breakdown of  the sensor may occur. 

WARNING

Danger of electric shock

Place the housing cover. If wiring is to be exposed, break the knockout.

4. Mounting the housing cover

X

H

Y

Sensor

Door

Header

Floor

a. Place the mounting template at the desired mounting position.

    (When setting the detection area close to the door, mount the sensor according to the chart below.)

b. Drill two mounting holes of ø3.4 mm (ø1/8").

c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").

d. Remove the mounting template.

e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.

Make sure not to mount the sensor lower than the bottom of header.

1. Mounting

H

 : Height from the floor to the bottom of the header

     (The mounting height is "

H

 + 

Y

".)

Y

 : Distance between the bottom of the header and the sensor

X

 : Distance between the door and the mounting surface

NOTE

CAUTION

Risk of getting caught

Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there

may be no detection area around the threshold. Install the sensor as low as possible on the header.

2. Wiring

Wire the cable to the door controller.

Before starting the procedure, make sure that the power is turned OFF. When passing the cable through the hole, do

not tear the shield otherwise it may cause electric shock or breakdown of the sensor.

Danger of electric shock

WARNING

Make sure to connect the cable correctly to the door controller before turning the power ON.

When turning the power ON or after adjusting the settings, do not enter the detection area for more

than 10 s in order to enable the presence detection.

a. Plug the connector.

b. Supply power to the sensor. Adjust the detection area and set the dipswitches. 

    (See 

Adjustments 4. Dipswitch settings

)

3. Turn ON the power

NOTE

Power

supply

Safety

output

Activation

output

2

1

3

12 to 24 VAC ±10 %

12 to 30 VDC ±10 %
COM.

N.C.

1.Grey
2.Grey
3.White
4.Yellow
5.Green
6.White stripe
7.Yellow stripe
8.Green stripe

N.O.

COM.

N.C.

N.O.

[mm(inch)]

38(1 1/2")

61(2 3/8")

267(10 1/2")

125(4 15/16") 

36(1 7/16") 

43(1 11/16") 

7.5 (5/16")

2.00 (6'7")

0.07 (3")

0.05 (2")

0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
1.86 (6'1")
2.52 (8'3")

2.50 (8'2")

0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51 (4'11")

0.07 (3")

2.32 (7'7")
3.15 (10'4")

3.00 (9'10")

0.11 (4")
0.34 (1'1")
0.53 (1'9")
0.89 (2'11")
1.81 (5'11")

0.08 (3")

2.79 (9'2")
3.79 (12'5")

3.50 (11'6")

0.12 (5")
0.39 (1'3")
0.61 (2')
1.03 (3'5")
2.11 (6'11")

0.09 (4")

3.25 (10'8")
4.42 (14'6")

2.20 (7'3")

0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")

0.06 (2")

2.05 (6'9")
2.78 (9'1")

2.70 (8'10")

0.10 (4")
0.31 (1')
0.48 (1'7")
0.80 (2'7")
1.63 (5'4")

0.07 (3")

2.51 (8'3")
3.40 (11'2")

A
B
C
D
E
F

G
H

I

I

H

G

Maximum mounting distance (

Y

)

X

2.00 (6'7")

0

No limit

0.05 (2")
0.10 (4")

0.11 (4")

0.15 (6")

0.10 (4")

0.20 (8")

-

0.25 (10")
0.30 (12")

-

H

0.13 (5")

-

2.50 (8'2")

0.13 (5")
0.12 (5")
0.11 (4")
0.10 (4")

-

0.09 (4")

[m (feet,inch)]

3.00 (9'10")

3.50 (11'6")

0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")

-

0
0
0
0
0
0

2.30 (7'7")

0.13 (5")
0.12 (5")
0.10 (4")
0.09 (4")

-

-

2.80 (9'2")

0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")

-

Отзывы: