2’7” to 3’11”

(0.8 to 1.2m)

Parallel

It’s extremely important to stay 

within recommend heights of 

2ft.,7in. to 3ft.,11in. to prevent 

missed and unwanted alarms. 

MOUNTING HEIGHT

FitLink QUICK REFERENCE GUIDE

DETECTION RANGE

MOUNTING POSITION

Make sure to adjust detection range to 

best fit application.

16.4' (5m) or 6.6' (2m)

Make sure to keep detector vertical and 

level to the ground. When mounting 

detector, do not tilt, turn upside down, or 

mount horizontal. Detector should alway be 

mounted vertical for best operation. 

4

FINAL TESTING

Make sure to insert battery to power 

detector and perform Walk Test.

After unit has been installed and 

programmed, make sure to walk test and 

confirm detector is performing affectively. 

Once confirmed be sure to flip dip switch #1 

from TEST (factory setting) to NORMAL.

TEST:

Regardless of DIP switch 4 (LED) and DIP 

switch 2 (BATTERY SAVING MODE) 

settings, LED will illuminate and detector will 

trigger every time.

This is used for Walk Test 

ONLY.

NORMAL:

The LED lights depending on the DIP switch 

4 (LED) setting and DIP switch 2 (BATTERY 

SAVING MODE) setting is active.

Horizontal

Upside Down

Tilt

If 6.6’ (2m) is required, rotate the 

lower lens 180 degrees. 

Do not remove the upper lens. 

Note>>

16.4ft. (5m) detection length (Factory default)

6.6ft. (2m) detection length

3.3

3.9

(ft)

2.6

 

3.3

0

6.6 9.8 13 16.4

(ft)

3.3

3.9

(ft)

2.6

0

6.6 9.8 13 16.4

(ft)

Side view

Side view

ON

1 2 3 4 5 6

  

TEST

NORM

Not detected

Detected