1
3
2
2’7” to 3’11”
(0.8 to 1.2m)
Parallel
It’s extremely important to stay
within recommend heights of
2ft.,7in. to 3ft.,11in. to prevent
missed and unwanted alarms.
MOUNTING HEIGHT
FitLink QUICK REFERENCE GUIDE
DETECTION RANGE
MOUNTING POSITION
Make sure to adjust detection range to
best fit application.
16.4' (5m) or 6.6' (2m)
Make sure to keep detector vertical and
level to the ground. When mounting
detector, do not tilt, turn upside down, or
mount horizontal. Detector should alway be
mounted vertical for best operation.
4
FINAL TESTING
Make sure to insert battery to power
detector and perform Walk Test.
After unit has been installed and
programmed, make sure to walk test and
confirm detector is performing affectively.
Once confirmed be sure to flip dip switch #1
from TEST (factory setting) to NORMAL.
TEST:
Regardless of DIP switch 4 (LED) and DIP
switch 2 (BATTERY SAVING MODE)
settings, LED will illuminate and detector will
trigger every time.
This is used for Walk Test
ONLY.
NORMAL:
The LED lights depending on the DIP switch
4 (LED) setting and DIP switch 2 (BATTERY
SAVING MODE) setting is active.
Horizontal
Upside Down
Tilt
If 6.6’ (2m) is required, rotate the
lower lens 180 degrees.
Do not remove the upper lens.
Note>>
16.4ft. (5m) detection length (Factory default)
6.6ft. (2m) detection length
3.3
3.9
(ft)
2.6
3.3
0
6.6 9.8 13 16.4
(ft)
3.3
3.9
(ft)
2.6
0
6.6 9.8 13 16.4
(ft)
Side view
Side view
ON
1 2 3 4 5 6
TEST
NORM
Not detected
Detected