background image

N219

CONTENTS

1  INTRODUCTION

1-1  BEFORE INSTALLATION ................2
1-2  PARTS IDENTIFICATION ................3
1-3  DETECTION AREA..........................3

2  INSTALLATION

2-1  INSTALLATION ................................4

3  WALK TEST

3-1  WALK TEST .....................................7

4  DIP SWITCH SETTING

4-1  LED ..................................................8
4-2  ALARM OUTPUT .............................8
4-3  PIR SENSITIVITY ............................8
4-4  ANTI-MASKING ...............................8

5  OTHERS

5-1  WALL TAMPER (OPTION) 

CONNECTION.................................9

5-2  EXAMPLE OF EOL WIRING .........10
5-3  LED LIGHT PATTERN ................... 11

6  SPECIFICATIONS

6-1  SPECIFICATIONS ......................... 11
6-2  DIMENSIONS ................................12

FTN-ST

Standard model with 2 PIRs

FTN-AM

FTN-ST with anti-masking

Compact design

190° adjustable bracket

Intelligent AND logic

Digital anti-masking (AM model)

Wall tamper (option)

NO.59-1645-1

INSTALLATION INSTRUCTIONS

Compact outdoor 
detector

Compact outdoor 
detector

fit

 series 

fit

 series

- 1 -

Содержание Fit FTN-AM

Страница 1: ...SKING 8 5 OTHERS 5 1 WALL TAMPER OPTION CONNECTION 9 5 2 EXAMPLE OF EOL WIRING 10 5 3 LED LIGHT PATTERN 11 6 SPECIFICATIONS 6 1 SPECIFICATIONS 11 6 2 DIMENSIONS 12 FTN ST Standard model with 2 PIRs FT...

Страница 2: ...amage The check mark indicates recommendation The nix sign indicates prohibition Warning Caution Do not remove the PCB Do not touch the PCB except for the DIP switch ON 2 3 4 1 Mounting height Keep th...

Страница 3: ...et Sponge Fixture Main unit Main unit cover Lens Screw kit Screw 3 20 mm 0 5 10 15 0 8 0 m 1 0 1 2 2 7 0 ft 3 3 3 11 1 0 2 3 4 5 m ft 0 5 10 15 0 8 0 m 1 0 1 2 1 0 2 3 4 5 m 2 7 0 ft 3 3 3 11 ft 1 3 D...

Страница 4: ...from the wall through the wiring hole in the bottom of the bracket and mount the bracket on the wall Note For wall tamper wiring option refer to page 9 Screw 3 20 mm Screw 3 20 mm Mounting height 0 8...

Страница 5: ...6 070 720 2 360 1 570 5 150 Power input Power input Alarm output COM Spare Tamper Power input Power input Alarm output COM Trouble output Tamper FTN ST FTN AM Power input Power input Alarm output COM...

Страница 6: ...m 1 0 1 2 2 7 0 ft 3 3 3 11 1 0 2 3 4 5 m ft 0 5 10 15 2 7 0 ft 3 3 3 11 0 8 0 m 1 0 1 2 ft 1 0 2 3 4 5 m Side view 5 m detection length Factory default 2 m detection length Side view 0 5 10 15 0 8 0...

Страница 7: ...DIP switch ON 1 2 3 4 ON 1 2 3 4 DIP switch 2 Check that LED lights for 2 seconds when the intended object is detected 1 Set DIP switch 1 LED to ON Note The switch is set to ON by factory default ON 1...

Страница 8: ...FTN ST FTN AM ON 1 2 3 4 STD LOW Position Function STD Factory default Normal sensitivity LOW Low sensitivity 4 4 ANTI MASKING DIP switch 4 FTN ST FTN AM ON 1 2 3 4 Position Function ON Factory defau...

Страница 9: ...eration has started set the DIP switch 4 ANTI MASKING to OFF and then to ON and close the cover Please close the main unit cover before turning on the power supply Teaching mode will begin immediately...

Страница 10: ...e for the fit series detector according to the following diagram Double EOL Triple EOL 1 2 3 4 5 6 7 Alarm relay Trouble relay Tamper Tamper EOL Resistance Alarm EOL Resistance Control panel Control p...

Страница 11: ...imit 2 m 5 m 6 7 16 5 Detectable speed 0 3 1 5 m s 1 4 11 s Sensitivity 2 0 C at 0 6 m s 3 6 F at 2 s Operating voltage 9 5 18 V DC Current draw 17 mA max at 12 V DC 20 mA max at 12 V DC Alarm period...

Страница 12: ...w optexchina com OPTEX CO LTD JAPAN ISO 9001 Certified ISO 14001 Certified 5 8 12 Ogoto Otsu Shiga 520 0101 JAPAN TEL 81 77 579 8670 FAX 81 77 579 8190 URL http www optex co jp e OPTEX EUROPE LTD UK T...

Отзывы: