User Manual
Advanced Console Server & RIM Gateway User Manual
95
Select the
Authentication Type
required. Access is denied to remote users attempting to connect using an
authentication scheme weaker than the selected scheme. The schemes are described below, from strongest to
weakest.
Encrypted Authentication (MS-CHAP v2):
The strongest type of authentication to use; this is the
recommended option
Weakly Encrypted Authentication (CHAP):
This is the weakest type of encrypted password authentication
to use. It is not recommended that clients connect using this as it provides very little password protection.
Also note that clients connecting using CHAP are unable to encrypt traffic
Unencrypted Authentication (PAP):
This is plain text password authentication. When using this type of
authentication, the client password is transmitted unencrypted.
None
Select the
Required Encryption Level
. Access is denied to remote users attempting to connect not using this
encryption level. Strong
40 bit or 128 bit encryption
is recommended
Note:
Firmware V3.5.2 and beyond support multiple dial-in users, who are setup with
dialin
Group membership. The
User name
and
Password
to be used for the dial-in PPP link, and any dial-back phone numbers are configured
when the User is set up. Earlier firmware only supported one PPP dial-in account
Note
Chapter 13 (Advanced Configurations) has examples of Linux commands that can be used to control the modem
port operation at the command line level
5.2.2
Using SDT Connector client
Administrators
can use their
SDT Connector
client to set up secure OoB dial-in access to remote
console servers
. The
SDT Connector
Java client software provides point-and-click secure remote access. OoB access uses an alternate path
for connecting to the
console server
to that used for regular data traffic.
Starting an OoB connection in
SDT Connector
may be achieved by initiating a dial up connection, or adding an alternate
route to the
console server
.
SDT Connector
allows for maximum flexibility is this regard, by allowing you to provide your
own scripts or commands for starting and stopping the OoB connection. Refer
Chapter 6.5
5.2.3
Set up Windows XP/ 2003/Vista/7 client
Open
Network Connections
in Control Panel and click the
New Connection Wizard
Select
Connect to the Internet
and click
Next
On the
Getting Ready
screen select
Set up my connection manually
and click
Next
On the
Internet Connection
screen select
Connect using a dial-up modem
and click
Next
Enter a
Connection Name
(any name you choose) and the dial-up
Phone number
that will connect thru to the
console server
modem
Enter the PPP
User name
and
Password
for have set up for the
console server
5.2.4
Set up earlier Windows clients
For Windows 2000, the PPP client set up procedure is the same as above, except you get to the
Dial-Up
Networking Folder
by clicking the
Start
button and selecting
Settings.
Then click
Network and Dial-up
Connections
and click
Make New Connection
Similarly for Windows 98 you double click
My Computer
on the Desktop, then open
Dial-Up Networking
and
double click
Make New Connection
and proceed as above
Содержание ACM5000
Страница 3: ......
Страница 10: ...Table of Contents 10 Console Server RIM Gateway User Manual...
Страница 11: ......
Страница 94: ...Chapter 5 Firewall Failover and Out of Band 94 Console Server RIM Gateway User Manual...
Страница 119: ......
Страница 149: ......
Страница 191: ......
Страница 205: ......
Страница 225: ......
Страница 303: ......
Страница 313: ......
Страница 323: ......