Mounting the enclosure
HC18A
18” cover
Mounting the H290/H291 AC outlet accessory
The H290/H291 accessory brings AC
power inside the H318 and H336
enclosures. The H290/H291 gives the
installer a clean location to mount power
adapters. Mount the H290/H291 in any
corner of the enclosure using the four #6
screws provided. Installation of AC outlets
should be done only by a qualified
electrician.
1/2” knockouts for 120VAC
The H290/(H291) provides
space for 4/(2) standard duplex
receptacles. Wires should exit
the H290/(H291) using the
grommets provided. The
grommets may be cut as shown.
Use H271 (not included) to
join 2 or more enclosures.
After cabling is routed, reverse paint
shield and return it to the enclosure to
protect cabling.
If H290 is installed, fold flaps on the paint
shield to bend the shield over the H290 AC
outlet accessory.
An old electrician’s trick
…
When hanging a heavy cabinet cover,
insert two nails (included) through the
mounting holes on the cover. Guide the
nails into the mating holes on the
enclosure and let the cover hang from
the nails while you attach the screws.
Installing the cover
1
2
3
1) Hook from the top
2) Swing into place
3) Push button to lock
OpenHouse modules attach from the top
H290/H291 installs in any of 4 locations
Grounding the cabinet
When used with model H290/H291 accessory, the grounding lug on
the H290/H291 is used. Standard #10-32 grounding screws may be
added to the tapped holes top or bottom.
Wallboard
Stud
Enclosure
1/8”
When mounting without using
the mounting tabs adjust the
enclosure to protrude 1/8”
beyond the wallboard surface.
1) Fold back tip of
wire tie and insert
into hole
2) Push wire tie slowly
into hole until tip
snaps to next hole
3) Pull tip through
second hole
4) Works
horizontally too
®
Using wire ties with the OpenHouse grid
AC outlet
accessories
H290
H291
Slots A - For 3/8” wallboard
Slots B - For 1/2” wallboard
Slots C - For 5/8” wallboard
A. Select the proper slots for the wallboard thickness.
B. Insert m o u n t i n g tab.
1. For tab mounting, install the mounting tabs
2. Attach enclosure
Optional lock kit - H208
Remove knockouts on the cover to install optional lock kit H208. If an H290/H291
is used the cover must be fastened to the enclosure using the included screws
(even when using the lock kit.) This is a UL requirement.
Installing cables
Remove the knockouts as needed
and line the holes with the grommets provided.
H272
ChannelPlus
Enclosures
®
Use the four screws provided.
(The screws will force mounting tabs
flat, tightening the tab.)
Or
, when mounting without
the tabs, use screws in the
four slide mount slots.
Wood
Stud
H318
18” enclosure
Remove paint shield and save.
Route cabling into enclosure.
H271
Coupling tube
ChannelPlus model H616
Telephone Master Hub (4 lines x 6 phones)
Telephones
From
Telco
RJ31X
Out
Expansion
Ports
R
T
4
R
T
3
R
T
2
R
T
1
A
B
C
The H318 and H336 enclosures include
H272 grommets. If you need more
grommets, they are available as part
number H272.
(Don’t worry if the tabs seem
loose - they tighten up when
screwed to the studs.)
H272
Grommet
HC36A
36” cover
H336
36” enclosure
16" on
center
B
A
C
OEM
AC ADAPTER
PRINTER'S INSTRUCTIONS:
INSTR,INSTL,H318/H336 - LINEAR P/N: 222683 B - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000" X 15.000" - FOLDING: 2-FOLD ALTERNATE, 2-FOLD HORIZONTAL INTO THIRDS (FINISH HAS LOGOS SHOWING) - SCALE: 1-1 - SIDE 1 OF 2 (FRONT)