HT-5200
Handheld Tachometer
Instruction Manual
ONOSOKKI
ONO SOKKI CO., LTD.
Страница 1: ...HT 5200 Handheld Tachometer Instruction Manual ONOSOKKI ONO SOKKI CO LTD...
Страница 2: ...notice 3 This document has been produced based on a series of strict verifications and inspections Should a failure occur nonetheless please inform our sales representative or sales office 4 Ono Sokki...
Страница 3: ...umidity Do not drop the HT 5200 or otherwise subject it to shock The HT 5200 contains precision electronics components Do not drop it and avoid subjection it to severe shock Take care that the lens of...
Страница 4: ...be extremely careful with safety precautions Particular care is required in making measurements over 10 000 r min When using the circumferential ring to measure tan gential speed take care with measu...
Страница 5: ...MODES TO SWITCH SETTINGS AND UNITS 13 5 MEASUREMENT PREPARATION 15 5 1 Non Contact Measurements 15 5 2 Contact Measurements 16 6 MEASUREMENT METHODS 17 7 OPERATION GUIDE 22 8 OTHER FUNCTIONS 23 8 1 Pu...
Страница 6: ...asurement Section 34 12 2 Detection Section 36 12 3 Pulse Output 37 12 4 Storage Time 38 12 5 Calculation Method 38 12 6 General Specifications 38 13 OUTER DIMENSIONS 39 14 STORAGE METHOD 39 15 WARRAN...
Страница 7: ...Selectable measurement units r min r s m min count ms Direct reading measurement of tangential speed MAX and MIN modes display maximum and minimum val ues except for count mode A memory recall functi...
Страница 8: ...rrying Case Reflective Marks 1 3 Options Separately Sold AX 1200 Pulse Output Cable PB 703 AC Adaptor HT 011 Reflective Marks 10 sheets with 250 marks mea suring 12 mm 12 mm KS 100 Circumferential Rin...
Страница 9: ...5200 DIGITAL TACHOMETER IND UNIT MODE RECALL MAX MIN H BATT OVER COUNT PERIOD m min r s ms r min MAX MIN H BATT OVER COUNT PERIOD m min r s ms r min ONOSOKKI LIGHT ON OFF 5 4 3 2 1 0 9 8 7 6 5 4 3 2...
Страница 10: ...asured values in all modes Detection section This light projector receiver is used in detected light reflected from the reflected mark i e the rpm signal UNIT switch refer to page 20 through 22 Each t...
Страница 11: ...e output signal for the CF 1200 Analyzer or other external device Use the AX 1200 cable op tion to make connection to this connector PULSE OUT switch refer to page 23 This switch is used to select eit...
Страница 12: ...o page 17 only for non contact measurement OVER indicator This indicator appears in the display when the measured value exceeds the measurement range Mode indicators refer to pages 13 and 20 21 MAX Ma...
Страница 13: ...ator appears together with the ms indicator when the HT 5200 is measuring period g HT 0501 Contact Adaptor refer to pages 16 and 22 This adaptor is mounted to the HT 5200 and used to convert the HT 52...
Страница 14: ...in the display replace the batteries When replacing batteries be sure to always replace all 3 at the same time Battery Replacement Method Lift up the battery cover while pushing the button of the bat...
Страница 15: ...NITS Display units and symbols UNIT Switch MODE Switch RPM r min r s Tangen speed Period Accum count m min Period ms Count r min r s m min Period ms r min r s m min Period ms MAX display MIN display N...
Страница 16: ...units The unit mm s does not appear on the display UNIT Switch MODE Switch RPM r min r s Tangen speed Period Accum count m min mm s m min mm s m min mm s Period ms Count r min r s Period ms r min r s...
Страница 17: ...is applied is shiny e g a plated surface either make measurements at an angle re moved from the perpendicular to this surface or paint the surface black before applying the reflective mark Press the...
Страница 18: ...display comes on Mount the KS 300 Contact Tip and use the UNIT switch to select the measurement units r min r s or ms Press the contact tip up against the rotating shaft to be mea sured so that there...
Страница 19: ...a ro tating body The rpm display is updated every 1 s The setting described be low enables direct reading of tangential speed Setting method A Set the diameter of the ro tating body on the preset swit...
Страница 20: ...Circum ferential Ring to the detec tion shaft being sure that the pin of the shaft fits into the slot of the ring As shown in the figure press the circumferential ring up against the object under mea...
Страница 21: ...to the detec tion shaft Measure in r min units Measurement precautions are the same as for the KS 200 With this measurement unit measurement is per formed of the period of the periodic rotational pul...
Страница 22: ...B If during counting the power is switched off and recall is made from memory all val ues with other measure ment units will be dis played as 0 Analog output is not avail able In this mode press RESE...
Страница 23: ...easurement is started press RESET with the rotational signal ap plied If the measurement is stopped with the power ap plied 0 r min will be held as the minimum value If you wish to hold the mini mum v...
Страница 24: ...n MODE Switch NORMAL measurement MAX measurement MIN measurement Contact tip KS 300 Curcum ring KS 200 m min KS 100 mm s Contact Method HT 0501 Contact Adaptor Measurement Power Switch ON position HOL...
Страница 25: ...cted light from a rotating body is detected by the sensor The pulse output is available for all the measurement modes and units The pulse output is used as a timing clock signal for rpm analy sis usin...
Страница 26: ...value on the display at the instant the power was switched off If a dark location makes reading the display difficult use back lighting 8 3 Alarm Function Setting For example suppose we wish to sound...
Страница 27: ...left of 100 r s 10 r s and 1 r s If you are using batteries for power reinstall the batteries and replace the battery cover After the above setting has been made when an actual mea surement is perform...
Страница 28: ...om the perpendicular 2 Method of Shining Light Onto the Reflective Mark The HT 5200 measures r min by the existence or lack of reflected light Detection will therefore not be possible if light is con...
Страница 29: ...of the circumference 80 000 to 100 000 r min X Y 0 4 less than 2 5 of the circumference Position of reflective mark application In order for the HT 5200 to be able to detect the rotational signal ligh...
Страница 30: ...k to circumference indicated in is not exceeded 5 Cases in Which Application of the Reflective Mark is Not Possible If for some reason it is not possible to apply the reflective mark to the rotating b...
Страница 31: ...autions listed below When mounting the contact adaptor to the HT 5200 insert the adaptor securely onto the detector section of the HT 5200 securing it tightly with a screw Also be sure that measure me...
Страница 32: ...is eccentricity between the center of rotating and the shaft cen ter an extremely hazardous condition will occur In particular if the contact tip deteriorates or if the method of pressing it up again...
Страница 33: ...ator will appear in the display and a beeper will sound as a warning Contact measurements When the measured value exceeds 20000 r min 400 00 r s or 2000 0 m min the value will be fixed on the display...
Страница 34: ...talled with correct and polarities Batteries worn down AC adaptor in serted into AC outlet Is there a reflec tive mark ap plied to the ro tating body Is the light pro jector shining light on reflec ti...
Страница 35: ...stance proper Correction The distance range over which measurement is pos sible is 20 to 300 mm Keep the distance in this range However depending upon how the reflective mark is applied e g when it is...
Страница 36: ...6 to 20000 r min 0 10 to 400 00 r s 0 6 to 400 0 m min 0 to 99999 counts 0 6 to 9999 9 ms Number of display digits 5 Display type 5 digit LCD liquid crystal display with backlighting Time base Quartz...
Страница 37: ...l speed the accuracy depends upon the rpm speeds of the rotating body Example For a diameter of 10 cm if the tan gential speed is 1000 m min the r min corresponding to this speed is 3183 1 r min and t...
Страница 38: ...ceeds 20000 r min 400 00 r s or 2000 0 m min the value will be fixed on the display the OVER indica tor will appear in the display and a beeper will sound as a warning 12 2 Detection Section Detection...
Страница 39: ...eflective mark are mutually perpendicular 12 3 Pulse Output Output voltage Hi 4 5 V min load resistance 100 k min Lo 0 5 V max sink current 2 mA Output impedance Approx 50 Output connector Pin jack 2...
Страница 40: ...r min is displayed the CPU performs a pre diction calculation 12 6 General Specifications Power requirements Type AA batteries Continuous operation time using manganese batteries at 20 Approx 40 hour...
Страница 41: ...ing high humidity and locations which are subject to direct sunlight Store the HT 523900 in a location having good ventilation If the HT 5200 is to be left for a long period unused be sure to remove i...
Страница 42: ...ollowing failures will be handled on a fee basis even dur ing the warranty period a Failures occurring through misuse mis operation or modi fication b Failures occurring through mishandling dropping o...