ONOSOKKI DS-0501 Скачать руководство пользователя страница 1

A4/58頁/両面モノクロ

-Specifications-

Instruction Manual

Data Station

DS-

5000

 Series

900000581 / IM20082502(1.2)

Содержание DS-0501

Страница 1: ...A4 58 Specifications Instruction Manual Data Station DS 5000 Series 900000581 IM20082502 1 2...

Страница 2: ...ll rights reserved 1 This product is covered by a warranty for a period of one year from the date of purchase 2 This warranty covers free of charge repair for defects judged to be the responsibility o...

Страница 3: ...k 42 Vpk 42 Vpk 42 Vpk 42 Vpk USB SD CARD DS 5100 Data Station BATTERY Notations Used in Instruction Manual This manual uses the following symbols as well as safety and caution symbols Check these bef...

Страница 4: ...ions are not followed WARNING Indicates a hazardous situation that if not avoided will result in death or serious injury CAUTION Indicates a hazardous situation that if not avoided may result in minor...

Страница 5: ...ct your nearest Ono Sokki sales office or the distributor where you purchased the product Continuing to use the product while an abnormality occurs may cause fire Do not insert a wire or piece of meta...

Страница 6: ...putting chemicals on the power cable placing an object on the power cable modifying or repairing the power cable fixing the power cable using a stapler or the like and using the damaged power cable d...

Страница 7: ...series Data Station may topple causing damage to the peripheral devices Precautions for Maintenance and Handling of Built in Devices WARNING Do not disassemble repair or modify the devices Never disas...

Страница 8: ...terrupted instantaneously If the power supply to the main unit is interrupted instantaneously wait for recovery from the power failure without doing anything or supply another power Precautions for Re...

Страница 9: ...tity Remarks 1 AC adapter 1 2 Power cable for AC adapter 1 3 Instruction manual 1 This manual 4 LAN cable 3 m 1 Connects the DS 5000 series Data Station with a personal computer CAUTION If any of the...

Страница 10: ...viii...

Страница 11: ...00 Main Unit 11 2 2 1 Overview of Main Unit 11 2 2 2 Parts Names and Functions of Main Unit 11 2 3 DS 5100 Main Unit Specifications 13 3 DS 0501 Battery Unit For DS 5000 series 16 3 1 Precautions for...

Страница 12: ...0544 4ch External Input Unit 32 5 2 3 Parts Names and Functions of DS 0543 2ch External Input 1ch Signal Output Unit 33 5 3 External Input Unit Specifications 34 5 3 1 DS 0542 2ch 0544 4ch External I...

Страница 13: ...dware Connection Method 42 7 3 1 About Hardware Connection Cable 42 7 3 2 Hardware to Hardware Connection Procedure 43 7 3 3 Startup in Hardware to Hardware Connection State and Hardware Recognition 4...

Страница 14: ...Table of Contents...

Страница 15: ...with maximum 96 channels CPU Intel Core processor Intel Core i7 or higher grade and 8th Generation or later generation 4 cores and 8 threads or more and 1 8 GHz or more base clock frequency Recommende...

Страница 16: ...ormally due to the physical shape or influence of other software installed or peripheral devices When you plan to purchase a personal computer to be connected with the DS 5000 series we recommend that...

Страница 17: ...U3 3 5 inches then format the HDD on the personal computer Windows OS beforehand Manufacturer Product name Western Digital WD Purple series SEAGATE SkyHawk series CAUTION Before recording check your p...

Страница 18: ...42 Vpk 42 Vpk 42 Vpk 42 Vpk USB SD CARD DS 5100 Data Station BATTERY USB SD CARD DS 5100 Data Station 42 Vpk 42 Vpk 42 Vpk 42 Vpk 42 Vpk 42 Vpk 6 0DLQ 8QLW 6 6 6 6 DWWHU 8QLW RU 6 VHULHV 6 FK N QSXW 8...

Страница 19: ...0534 Input Unit DS 0532 2ch 100kHz Input Unit 4 DS 0523 0526 0532 0534 Input Unit DS 0534 4ch 100kHz Input Unit 4 DS 0523 0526 0532 0534 Input Unit DS 0542 2ch External Input Unit 5 DS 0542 0543 0544...

Страница 20: ...pk LAN SYNC IN OUT LAN SYNC 19 V 3 5 A MAX DC INPUT 10 28 V 6 0 A MAX DC INPUT MADE IN JAPAN ONO SOKKI Windows Embedded 9 VHULHV DVHU RSSOHU 9LEURPHWHU 13 VHULHV FFHOHURPHWHU ZLWK EXLOW LQ SUHDPSOLrHU...

Страница 21: ...PSOLrHU 9LEUDWRU 7 VHULHV DQGKHOG LJLWDO 7DFKRPHWHU 70 VHULHV LJLWDO 7DFKRPHWHU 03 VHULHV 5RWDWLRQ HWHFWRU 6SHDNHU 6 VHULHV DWD 6WDWLRQ FRQrJXUDWLRQ H DPSOH 6 0DLQ 8QLW HIWPRVW XQLW 6 DWWHU 8QLW RU 6...

Страница 22: ...1 2 DS 5000 Outside Dimensions 5 5 1 Overview of DS 5000 8...

Страница 23: ...he power supply to the main unit is interrupted instantaneously If the power supply to the main unit is interrupted instantaneously wait for recovery from the power failure without doing anything or s...

Страница 24: ...se For an SD card with protection switch be sure to release the lock before inserting the SD card If the SD card is inserted without releasing the lock data cannot be written Never remove an SD card w...

Страница 25: ...rdware connection cables between them 2 2 2 Parts Names and Functions of Main Unit USB SD CARD DS 5100 Data Station LCD with touch panel Power switch LED incorporated Hold down the switch for one seco...

Страница 26: ...AN OUT of another DS 5100 SYNC hardware connector OUT A hardware connector used when two or more units of the DS 5100 Main Unit are connected LAN RJ45 connector OUT A terminal used to connect a person...

Страница 27: ...connected after DS 0526 DS 0526 6ch 40kHz Input Unit DS 0532 2ch 100kHz Input Unit DS 0532 or DS 0534 1 unit DS 0532 x 2 unaccepted DS 0534 4ch 100kHz Input Unit DS 0542 2ch External Input Unit 1 uni...

Страница 28: ...C to the 10th one DS 5100 Interface Power switch Held down for 1 second or more to turn on off Power lamp Incorporated in the power switch LCD with touch panel Status display IP setting battery status...

Страница 29: ...rature range 20 to 60 C humidity 20 to 80 RH no dew condensation Mass Approx 1 800 g Cooling fan Provided on off switchable Applicable standards CE marking Low Voltage Directive LVD 2014 35 EU standar...

Страница 30: ...ately Do not throw the built in lithium ion battery into fire Throwing the built in lithium ion battery into fire putting it close to fire heating it or leaving it at a high temperature is dangerous b...

Страница 31: ...lithium ion battery specified by Ono Sokki Using an unspecified lithium ion battery is very dangerous because it may cause not only failure or malfunction but also generation of smoke fire electric sh...

Страница 32: ...be connected to the external DC power supply connector DC INPUT on the rear side of the DS 0501 Battery Unit For DS 5000 series The connected external DC power is supplied to each unit via the DS 510...

Страница 33: ...ry Battery slot cover fixing screw A screw fixing the battery slot cover Turn the screw counterclockwise to loosen it or clockwise to tighten it To replace the lithium ion battery contained inside loo...

Страница 34: ...unit it should be done within the recommended temperature range for charging 10 to 35 C in consideration of increase in temperature Note that if the battery pack is charged at a low ambient temperatur...

Страница 35: ...he power may be turned off automatically 3 2 4 Lithium ion Battery Mounting Procedure The DS 0501 Battery Unit For DS 5000 series is shipped without mounting the battery pack lithium ion battery Mount...

Страница 36: ...he battery pack is equipped with indicator lamps and switch to display the charge level When the charge level confirmation switch is pressed the indicator lamp turns on to display the charge level Cha...

Страница 37: ...020 99 6 Wh Drive time Approx 4 hours for main unit 6 ch input unit at outside temperature of 25 C Charging operation When AC adapter is connected Recommended temperature range for charging 10 to 35 C...

Страница 38: ...LED of the input unit blinks or turns on in red it indicates that the voltage range is exceeded due to excessive input The recorded data is unreliable Set the appropriate voltage range on the O Solut...

Страница 39: ...nnel is turned on in green by the application function Red light turns on blinks Input of a signal exceeding the set voltage range causes the light to turn on or blink in red Input channel number Inpu...

Страница 40: ...a signal exceeding the set voltage range causes the light to turn on or blink in red Input BNC connector Terminals used to input signals from various peripheral devices such as Ono Sokki s accelerati...

Страница 41: ...ltage range 30 0 30 dBVrms 3 ranges Maximum input voltage 30 Vrms 42 4 Vpk Absolute maximum input voltage 50 Vpk DC to 100 kHz DC offset 60 dB FS auto zero on DC connected Input level monitor Red LED...

Страница 42: ...iasing filter 3rd order Butterworth LPF 300 kHz 3 dB DS 0523 0526 40kHz Input Unit General Specifications Outside dimensions 40 mm W x 160 mm H x 221 mm D protrusions not included Power supply Supplie...

Страница 43: ...42 4 Vpk Absolute maximum input voltage 50 Vpk DC to 100 kHz DC offset 60 dB FS auto zero on DC connected Input level monitor Red LED turned on by excessive input turned on at range FS Frequency rang...

Страница 44: ...x 160 mm H x 221 mm D protrusions not included Power supply Supplied from main unit Power consumption Maximum 6 W Operating temperature range 10 to 50 C humidity 20 to 80 RH with no condensation Stora...

Страница 45: ...ound The occurrence of a short circuit may cause failure electric shock or damage CAUTION If the status LED of the DS 0542 0543 0544 external input channel blinks or turns on in red it indicates that...

Страница 46: ...it 42 Vpk 42 Vpk 42 Vpk 42 Vpk 42 Vpk 42 Vpk Status LED Green light turns on blinks Detection of input signal causes the light to turn on or blink in green Red light turns on blinks Input of a signal...

Страница 47: ...light to turn on in green Orange light turns on Overloaded output causes the light to turn on in orange Input BNC connector Terminals used to input external timing signals or revolution pulse signals...

Страница 48: ...Input frequency Maximum 300 kHz out of band filter 300 kHz 3 dB Number of input pulses revolution 0 5 to 3600 P R Input pulse division function 1 to 3600 divisions in increments of 1 Required when th...

Страница 49: ...lter 300 kHz 3 dB Number of input pulses revolution 0 5 to 3600 P R Input pulse division function 1 to 3600 divisions in increments of 1 Required when the input frequency exceeds 4 kHz Input pulse wav...

Страница 50: ...1 or 1 3 octave Pink filter Analog system 3 dB oct 1 0 dB specified at 20 Hz to 20 kHz Burst function Provided continuous single 1 ms to 32 s Number of burst cycles 1 to 32767 in increments of 1 Taper...

Страница 51: ...put connector and the frame ground Applying a voltage exceeding 42 Vpk may cause failure of the input channel for the summation function electric shock or damage CAUTION If the status LED of the outpu...

Страница 52: ...ght turns on Turning on of summation causes the light to turn on in green while the optional summation function is enabled Status LED Green light turns on Signal output ON causes the light to turn on...

Страница 53: ...dom no inter channel correlation pseudo random impulse octave band noise pink noise record data THD and spurious 75 dB or less sine wave 1 kHz amplitude 1 V output Applicable FFT analysis length 64 to...

Страница 54: ...put connector within the unit are isolated collectively Summation ratio 1 1 DS 0545 General Specifications Outside dimensions 40 mm W x 160 mm H x 221 mm D protrusions not included Power supply Suppli...

Страница 55: ...532 0534 100kHz Input Unit Be sure to hold the connector when connecting or disconnecting the cables Do not apply an excessive force to the cables There is a risk of failure or damage When the DS 5000...

Страница 56: ...multiple units of DS 5000 series Data Station having different channel numbers 3HUVRQDO FRPSXWHU QSXW K WR QSXW K WR 1 FDEOH IRU FRPPXQLFDWLRQ P DUGZDUH FRQQHFWLRQ FDEOH IRU V QFKURQL DWLRQ USB SD CA...

Страница 57: ...nits of DS 5100 Main Unit by connecting the cables between OUTs and INs for the LAN connector and the SYNC connector for synchronization In this example five units are connected Connect the LAN cable...

Страница 58: ...MAX DC INPUT MADE IN JAPAN ONO SOKKI Windows Embedded LAN SYNC IN OUT LAN SYNC 19 V 3 5 A MAX DC INPUT MADE IN JAPAN ONO SOKKI Windows Embedded 7 3 3 Startup in Hardware to Hardware Connection State...

Страница 59: ...ware connection cable for synchronization is connected wrongly in a manner unmatched with the LAN cable for communication as shown below the O Solution is started At this time the hardware B with the...

Страница 60: ...ltiple units of hardware the firmware versions must be identical to one another If the hardware units have different firmware versions a message prompting you to update the firmware will be displayed...

Страница 61: ...ll rights reserved 1 This product is covered by a warranty for a period of one year from the date of purchase 2 This warranty covers free of charge repair for defects judged to be the responsibility o...

Страница 62: ...A4 58 Specifications Instruction Manual Data Station DS 5000 Series 900000581 IM20082502 1 2...

Отзывы: