![Onlogic Factor 202 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/onlogic/factor-202/factor-202_product-manual_1638167019.webp)
3-Pin Terminal Block Power Connector
Mainboard power is applied to the FR201 platform by way of a 3-pin terminal block connector (Mating
part: Dinkle 2ESSM-03P
or equivalent
). The system is operational from 8V~24V. The maximum rated
current of the connector is 15A per pin. Use a wire gauge that is rated for the operational current. See
below for on-board connector pinout.
Note: DC power input should not be connected when the system is supplied with POE power via the
ADP122 add-on module.
Pin
Definition
1
GND
2
Chassis/Earth GND
3
12~24V VDC Input
3-Pin terminal power pinout
5-Pin COM Terminal Block
The serial port supports RS-232, RS-422, and RS-485 configurations by way of a 5-pin terminal block
connector (Mating part: Dinkle 0221-2005 or equivalent). The mode can be selected from within the
operating system using available configuration tools. See FR201 software documentation for details.
Pin
RS-232 RS-422
RS-485
1
GND
GND
GND
2
NC
TX-
TX-/RX-
3
NC
RX-
NC
4
RX
TX+
TX+/RX+
5
TX
RX+
NC
COM terminal pinout
LAN1 - CM4 output
The CM4 LAN Port on FR201 supports up to 1Gbps link speeds over standard shielded CAT5e or
CAT6 cables. The connector is the industry standard RJ45 connector. The LAN link state is shown by
the two LEDs enclosed in the port. Activity is also indicated by the LAN1 LED on the side of the
19
Содержание Factor 202
Страница 1: ...FR202 Product Manual ...
Страница 10: ...1 4 Exterior Features and Dimensions 1 4 1 Top I O 1 4 2 Bottom I O 10 ...
Страница 11: ...1 4 3 Factor 202 Dimensions FR202 11 ...
Страница 12: ...1 5 System Block Diagrams 12 ...
Страница 15: ... Active Low Sinking Output Compatible Input Wiring Active High Sourcing Output Compatible Input Wiring 15 ...
Страница 17: ...Sourcing Output Wiring 17 ...
Страница 18: ...Sinking Output Wiring 2 2 Bottom I O Definition 18 ...
Страница 30: ...30 ...