Страница 1: ... Help us to serve you better by registering your product for Warranty Web Register at w Telephone Post Visit Post the Warranty Registration Card ww onida com Call Centre No 0XX 39889000 0XX STD Code of State Capital Service Centre Copy or Visit the Nearest Service Centre Model W182FLT W183FLT 3 STAR 2 STAR ...

Страница 2: ...inuous improvement through innovation and human development to give customer better value for money always ONIDA stands committed to provide the ultimate customer satisfaction as nothing brings us greater joy than having satisfied customers of ONIDA At ONIDA feedback and suggestions based on your product usage experience is greatly appreciated Please contact to us at response onida com Chief Execu...

Страница 3: ...ectrical Requirements 17 Take care of your Air Conditioner 18 Precautions to be taken 19 Trouble Shooting Chart 21 Installation and Satisfaction Report 23 Warranty Terms Conditions 25 Preventive Maintenance Service Coupon 27 Warranty Card Customer Copy 29 Warranty Card service Center Copy 31 Inside Air Conditioner 2 ...

Страница 4: ... Code Aesthetics a Unique Flat Panel Performance b High BTU Compressor c Trapezoidal Inner Grooved Tube d Large Condenser Coil Features a Combined Timer b Auto Restart c Multi Fan Speeds Safety Reliability a Low Deration Factor b Hydrophilic Fins for Evaporator c 5 Stage Epoxy Polyester Painting d Rugged Construction With Thicker Gauge Steel 1 ...

Страница 5: ...ey Ÿ Adjust the temperature timer setting 4 Fan Speed Key Ÿ Toggles the Fan speed between High Low and Auto 5 Remote Sensor 6 Room Temp Display 7 Timer Key Ÿ Toggles between Timer ON and Timer OFF 8 Swing Key Ÿ To adjust the airflow direction The unit displayed in manual are for representational purpose only Actual unit may vary POWER TEMP TIME HIGH MID LOW DRY FAN COOL MODE SWING ON OFF TIMER ON ...

Страница 6: ...n the circuit The Time Delay ensures that the compressor switches ON only after a delay of about 3 minutes 2 Press the MODE Button for Auto Cool or selection 3 Press the FAN Button to set the Fan Speed Each press changes the fan speed from Low Med High Fan speed The selected fan setting symbol can be seen on the LCD 4 The Set Temp is displayed on LCD Press button to increase and to the decrease th...

Страница 7: ...lly step through the AUTO COOL DRY FAN modes and stop when DRY mode is selected 2 symbol can be seen on the Remote panel LED will glow on display panel when you select the DRY mode 3 In DRY mode Temperature and FAN Speed cannot change Default pre set 0 temperature is 25 C FAN will run at low speed Compressor work as per the Temperature difference AUTO FAN The FAN Mode 1 Press MODE button to cyclic...

Страница 8: ...airflow direction Press it again to stop OPERATIONS Vent Control CLOSE VENT OPEN CLOSE OPEN Vertical air flow adjustment manually The Vent control is located above the control knobs The operation is different on different models see below figures For maximum cooling efficiency CLOSE the vent This will allow internal air circulation OPEN the vent to discharge stale air To open the vent pull the lev...

Страница 9: ...n used together with a stive etc It may cause a n injury Water may enter th e uni t and degrade th e insulation It may cause a n electri c shock An oxygen shortage may occur To prevent injury to the user or other people and property damage the following instructions must be followed Ÿ Incorrect operation due to ignoring of instruction will cause harm or damage the seriousness is classified by the ...

Страница 10: ...rounded Installation of the Housing Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B Holes from the out...

Страница 11: ... the installation instruction 5 Switch unit on Check for operation of the unit and check for vibration in the installation 6 Fit the drain pan to the housing and run a drain line to a suitable location if required Pull out the Air return grids and remove three screws on the front board then take off the front board Remove the two screws at the bottom or on both sides of the package Hold the handle...

Страница 12: ...er Method I Block the drainage hole on one side of the unit base with a rubber stopper so as to let the condensing water flow out from the rear drainage hole of the unit as shown in Figure 1 1 a When this method is adopted the condensing water in the base plate cannot be drained completely The remaining water may improve the heat dispersing effect of the unit but with louder noise b Installation o...

Страница 13: ... to treat the condensed water For Cooling Only Models You can choose back drainage or non drainage See the following procedures to perform back drainage 1 Fit the seal onto the drain joint which provided with your air conditioner accessory 2 Remove the rubber plug from the back of the unit 3 Attach the drain joint to the back of the cabinet where you 0 remove the plug and rotate 90 to securely ass...

Страница 14: ...l obstructions to make the airflow paths free Change to COOL mode Make the selected temperature less than room temperature Clean the air filter TROUBLE SHOOTING CHART MCB has tripped Fuse has burnt Input voltage to the stabilizer is below acceptable range The On Off key is not pressed The airflow paths are not free The Units is in the fan mode Selected temperature is more than room temperature Air...

Страница 15: ... Grill Temp C Input Voltage Remote Operation Customer s Response To be filled up by the Customer 1 Installation completed within 12hrs 24 hrs 36 hrs more than 36 hrs 2 How did you find the behavior of the Engineer Excellent J Good K Not satisfied L 3 Overall rating of the service Excellent J Good K Not satisfied L 4 Suggestion if any Job Number Engineer s Signature Customer s Signature INSTALLATIO...

Страница 16: ...der the terms of this warranty are warranted only for the remaining period of the original warranty period 5 For attending any service call under this warranty beyond the municipal limits of the locality in which the authorized representative dealer is situated outstation locations all to and fro travelling and other incidental expenses as prevailing from time to time incurred in connection with t...

Страница 17: ...y the terms and conditions of this warranty 14 This warranty shall be deemed to have been issued at Mumbai state of Maharashtra and courts at Mumbai shall have exclusive jurisdiction on matters covered by or following from this warranty and the original purchaser alone shall have cause of action arising out of the transaction Preventive Maintenance Service 1 Date ________ Customer Identification N...

Страница 18: ... that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code MIRC Electronics Limited ...

Страница 19: ...l In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY FOR OFFICE USE ONLY Customer C...

Страница 20: ...NESS REPLY ENVELOPE ONIDA CUSTOMER RELATION CENTRE Adonis Electronics Pvt Ltd Onida House II Mukund Ground Floor Mahal Industrial Estate off Mahakali Caves Road Andheri East Mumbai Maharashtra India 400093 ...