OneVue™ Sense Differential Pressure Sensor

Installation Guide

Product Models: A120
09/25/19

Содержание A120

Страница 1: ...OneVue Sense Differential Pressure Sensor Installation Guide Product Models A120 09 25 19 ...

Страница 2: ...property of their respective owners The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG Inc and any use of such marks by Primex Inc is under license Primex is the leading provider of solutions to automate and maintain facility compliance increase efficiencies enhance safety and reduce risk for enterprise organizations in the healthcare education manufacturing and...

Страница 3: ...2 Mounting kit contents 13 Mounting guidelines 13 Step 1 Verify sensor configuration 14 Step 2 Insert sensor batteries and turn on battery power 14 Step 3 Route tubing between Controlled and Reference Space 15 Step 4 Mount sensor connect tubing and apply power 15 Step 5 Verify connection to OneVue 15 Step 6 Verify OneVue settings 16 Differential Pressure Install Enable door switch monitoring 18 Us...

Страница 4: ...um 1 5V batteries use of Energizer L91 Ultimate Lithium batteries recommended Estimated Battery Life Up to 18 months with use of Lithium 1 5V batteries estimation based on 1 hour Logging Interval 8 hour Check In Interval and adequate wireless signal Network Communication Wi Fi supported specifications Applies to All OneVue Sensors Wireless Networking Protocols 802 11b 11g 11n single stream 2 4 GHz...

Страница 5: ...38 W 1 90 cm x 3 50 cm LCD Display current sampled reading and operating status LED Status Indicator AC power input USB Mini B 5 pin connector Mounting wall or surface mount Environment Operating Temperature 32 to 122 F 0 to 50 C indoor use only Storage Temperature 4 to 140 F 20 to 60 C Certifications FDA registered 21 CFR Part 11 compliant FCC CE and IC compliant Warranty 1 Year Differential Pres...

Страница 6: ...A sample reading is taken every 5 seconds The unit inH2O or Pa is configured within the sensor profile in your OneVue account A Primex sensor continuously samples and monitors its sampled readings If its sampled readings are out of range for 60 consecutive seconds the sensor device automatically sends the out of range reading to OneVue OPEN Door Switch Monitoring enabled Door switch is in the Open...

Страница 7: ...r Check In Interval and adequate wireless signal If the device is powered by AC or Power over Ethernet PoE the yellow LED indicator flashes during this state Lbat Device is an Alarm state due to its battery level is critically low Readings are not logged or transmitted your OneVue account during this state Up A firmware update is being applied to the device Readings are not displayed sampled or lo...

Страница 8: ...tatus Device power Green LED illuminated Normal state Operating as expected AC or PoE power LED illuminated Battery power only LED disabled to conserve battery life Upon power up illuminates for 2 seconds Yellow LED flashing Warning state Low battery Unresponsive Alarm state No Temp Probe or Water Detector AC or PoE power LED illuminated and flashes Refer to the LCD display to identify the conditi...

Страница 9: ...ery power use only When operating solely on battery backup power estimated battery life is 7 days This estimation is based on the use of Lithium 1 5V batteries 1 hour Logging Interval 8 hour Check In Interval and adequate wireless signal Use of alkaline batteries is not recommended Power over Ethernet PoE Temperature Temperature and Humidity Differential Pressure Water Leak and Contact Closure Sen...

Страница 10: ...al door switch monitoring feature This feature is designed to monitor whether a door in the room being monitored is open or closed when a door is intentionally left open for an extended period of time signaling that the room is not in use When a door status change is detected the sensor device automatically transmits the door status to OneVue To enable the door monitoring feature the sensor s devi...

Страница 11: ...ting statuses but the data is only logged and stored in your OneVue account OneVue does not monitor the sensor readings or device operating status and disables the alerts assigned to the Monitored Asset during the Alarms Disabled state 4 When the door switch changes from an Open status to a Closed status the device automatically transmits the Closed status to OneVue The sensor and its Monitored As...

Страница 12: ...82 m 1 8 in 3 17 mm inner diameter I D 1 4 in 6 3 5 mm outer diameter O D 1 AC power supply 5V DC USB Mini B 5 pin connector interface 5 ft 1 5 m cable Input 100 240 VAC 50 60 Hz 0 4A Output 5V DC 1 0A max 1 Primex 3 0v Lithium Iron Disulfide Battery Pack contains 2 AA 1 5V Energizer Ultimate Lithium batteries Estimated battery life Up to 18 months with use of Lithium 1 5V batteries estimation bas...

Страница 13: ...ocation that would interfere with the use of the monitored unit or area Wireless Network use It s recommended that the device is in a clear line of sight to a wireless access point If the location is NOT in a clear line of sight to a wireless access point its LCD screen must be above the unit it s being mounted to Wireless signal strength of 60db or better at the mounting location It s recommended...

Страница 14: ...e the extended tubing error rate Step 1 Verify sensor configuration Prior to installation a sensor device must be configured for use with OneVue A sensor is either configured prior to shipment through Device Preconfiguration or onsite using the OWDC app Device Preconfiguration completed white label with configured settings is affixed to the backside of the sensor Sensor has been configured with ne...

Страница 15: ...approximately 3 8 in 0 95 cm of the screw head exposed for hanging Attach device by sliding the key hole slot onto the mounting screw Ensure the device is properly secured and level Optionally mount to surface using the supplied 3M Dual Lock Fastener amp Tape 2 x 1 strips It s recommended to place the strip s horizontally 2 Attach tubing to appropriate port located on the bottom side of the sensor...

Страница 16: ...ngs Go to Monitoring Monitored Assets Each Primex sensor device is assigned to a Monitored Asset and its readings or monitored conditions generate the Monitored Asset s current and historical readings In addition sensor operating condition data is linked to its assigned Monitored Asset When a sensor enters a Warning or Alarm state its assigned Monitored Asset is also set to an Alarm or Warning sta...

Страница 17: ...hat is activated during a reading Alarm state Out of Range Past Alarm Delay status The audio alert is activated when a reading is out of range and the time period it has been out of range has exceeded the time period set in its Alarm Delay Logging Interval sensor gateway setting The Logging Interval is how frequent a sensor logs a reading and stores it into its internal memory All logged readings ...

Страница 18: ...ored When a room is not in use you can simply open the door to disable the monitoring of the room s differential pressure Enable door switch monitoring To enable the door monitoring feature the device door jumper must be enabled jumper removed and a door switch is required to be wired to the device door terminal block By factory default the door monitoring feature is disabled IMPORTANT For door sw...

Страница 19: ...the wire slot on the bottom plate cover make sure to reattach connecting cable to dual port sensor if previously removed Applying slight outward pressure on the sides of the sensor housing allows bottom plate to slide in Make sure the bottom plate slides into the retention tab slots on the housing 8 Reattach the device cover The sensor is now configured to monitor the door status set by the magnet...

Страница 20: ... PEAP v1 GTC Network Communication Protocols Hypertext Transfer Protocol Secure HTTPS TLS 1 2 IP Addressing Dynamic Host Configuration Protocol DHCP static IP addressing Data Packet Size typically less than 5 kilobytes kB Power over Ethernet PoE and Ethernet supported specifications Applies to OneVue Temperature Sensor Differential Pressure Sensor Water Leak Sensor Contact Closure Sensor OneVue Sy...

Страница 21: ...If firewall supports wildcards Domain filters URL filters primexonevue com us east 1 production s3 amazonaws com https primexonevue com https us east 1 production s3 amazonaws com If firewall does not support wildcards Domain filters URL filters console primexonevue com deviceapi alt primexonevue com deviceapi primexonevue com onevueapi primexonevue com us east 1 production s3 amazonaws com https ...

Страница 22: ...ges not expressly approved by Primex might cause harmful interference and void the FCC authorization to operate this product FCC Radio Frequency Interference This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential inst...

Страница 23: ...t or relocate the receiving antenna l Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be instal...

Страница 24: ...n any way including but not limited to attempted warranty repair other than by Primex or an authorized service partner Limitation of Liability The warranties and remedies contained herein are exclusive and in lieu of all other warranties express or implied or statutory including any liability arising under any warranty or merchantability or fitness for a particular purpose implied statutory or oth...

Страница 25: ...er technical support services for Primex products If you have purchased Primex products or have a service agreement with a Primex Partner they are your primary contact for all Technical Support inquires When contacting Technical Support Make sure you have satisfied the system requirements specified in the product documentation Also be at the computer or device on which the problem occurred in case...