Test Procedure for the NCP1615GEVB Evaluation Board

 

 

Table 1: Required Equipment 

*Chroma 61604 AC 

Power Source 

*Voltech PM3000A 

Power Analyzer 

*Agilent 34401A 

Multimeter 

*Agilent 34401A 

Multimeter 

*Chroma 6314 

Electronic Load with 

*Chroma 63108 High 

Voltage Module 

*Tektronix TDS5034B 

Oscilloscope with 

*Tektronix P5205 

Differential Probes 

*Equivalent test equipment may be substituted. 

Test Procedure: 
 

1.

 

Make sure jumper J4 (PSM) is connected.

 

2.

 

Connect  the electronic load with  high voltage module to  the output labeled “400 V/  300 
mA”. 

3.

 

Connect  one  of  the  multimeters  in  series  with  the  output  and  load  and  set  it  to  measure 
current. 

4.

 

Connect the second multimeter to the output and set it to measure voltage. 

5.

 

Connect the oscilloscope with differential probes to the output and set it to measure output 
ripple and frequency. 

6.

 

Connect the ac power source and power analyzer to the terminals labeled “Input”. Set the 
current compliance limit to 3 A.  

7.

 

Set the ac power source to 85 Vac / 60 Hz.  

8.

 

Set the high voltage electronic load to 300 mA. 

9.

 

Turn the AC source on. 

10.

 

Wait 10 seconds, and then check the output voltage (

V

OUT

) using the corresponding 

multimeter.  Verify it is within the limits of Table 2. 

11.

 

Measure power factor (

PF

) and input power (

P

IN

) using the power analyzer. 

12.

 

Measure the peak to peak voltage and frequency of the output ripple using the 
oscilloscope. 

13.

 

Measure 

I

OUT

 using the corresponding multimeter. 

14.

 

Calculate efficiency (

η

) using the equation:

%

100

IN

OUT

OUT

P

V

I

 

15.

 

Repeat steps 9-13 with the ac source set to 115 Vac / 60 Hz, 230 Vac / 50 Hz, 265 Vac / 
50 Hz. Verify the results are within the limits of Table 2.  

16.

 

Turn off the ac source.  

17.

 

Since high voltage will be present after the voltage is removed, wait for the dc voltmeter 
to show approximately 0 V before continuing.  

18.

 

Disconnect the ac source. 

19.

 

Disconnect the oscilloscope.  

20.

 

Disconnect the electronic load. 

21.

 

Disconnect both multimeters.  

22.

 

End of test.  