NCP1095GEVB

NCP1095 Evaluation Board
User's Manual

IEEE 802.3bt PoE-PD Interface Controller

Board

General

The NCP1095GEVB board allows easy implementation

and evaluation of a Power-over-Ethernet powered
equipment that is able to operate with an assigned power
level up to 90 W. The evaluation board is based on the PoE
PD Controller NCP1095 (U2) that uses an external
pass-switch (Q1) and sense resistor (R10). The board can
also facilitate the design of proprietary 100 W+
applications.

Figure 1. Operational NCP1095GEVB Showing

Basic Interconnections

The NCP1095GEVB board is designed as a PoE splitter:

having a PoE-enabled Ethernet port (labeled “PoE IN”) as
input and offering the power to a separate connector (J2)
while passing through the data to another Ethernet port
(labeled “E OUT”).

Quick Start Guide

Step 1: Connect the power connections available on
connector J2 (labeled “GND” and “VPP”) to the DC/DC
converter on the system that needs to be powered (cf. black
and red wires in the picture on the left). The DC/DC
converter behind the NCP1095 EVB should be operational
over a 34 V to 57 V voltage range.
Step 2: Connect the 

control connection

 to the DC/DC

converter! 

It is important that the DC/DC converter or

any significant load is kept off when the pass-switch is

charging the input capacitance.

For a DC-DC converter with an undervoltage (UV or

UVLO) or an active high enable (EN or SHDN), the “

PG

signal on connector J2 could be used (cf. green wire in the
picture on the left). The “PG” signal will be clamped to 18 V
by a zener when the board is powered up. For some DC-DC
converter boards an additional diode in series with the
control connection might be required (cathode connected to
NCP1095 and anode connected to the DC-DC converter).

For a DC-DC converter with an active low enable (EN or

SHDN or ON/OFF), the “nPG” signal on P1 could be used.
The “

nPG

” signal will be pulled up to VPP during the inrush

phase. Always check the voltage rating of the enable,
shutdown or undervoltage pin of the DC-DC converter.
Step 3: Insert the Ethernet cable (cf. blue cable in the picture
on the left) coming from the PSE in the Ethernet connector
J3 labeled “PoE IN”.

If the PSE powers up the system the green PGOOD LED

should be ON.

The status of the remaining LEDs depends on the PSE

being used.

www.onsemi.com

EVAL BOARD USER’S MANUAL

Содержание NCP1095GEVB

Страница 1: ...DC DC converter behind the NCP1095 EVB should be operational over a 34 V to 57 V voltage range Step 2 Connect the control connection to the DC DC converter It is important that the DC DC converter or any significant load is kept off when the pass switch is charging the input capacitance For a DC DC converter with an undervoltage UV or UVLO or an active high enable EN or SHDN the PG signal on conne...

Страница 2: ... 802 3af at PSE Type 1 or Type 2 on The PSE is categorized according to 802 3bt PSE Type 3 or Type 4 The PSE Type determines the MPS timing It also indicates to a PD requesting Autoclass whether it makes sense to go to the maximum power state according to its assigned Class System Startup A PD can be underpowered and assigned to Class 3 only Therefore the DC DC converter behind NCP1095GEVB should ...

Страница 3: ...NCP1095GEVB www onsemi com 3 Figure 2 Schematic Diagram NCP1095 EVB ...

Страница 4: ...nsert a high voltage 30 V auxiliary supply when the NCP1095GEVB is already powered by a PSE Violating the warning above may result in the PD sourcing power on the PoE IN Ethernet connector Figure 3 Operational NCP1095GEVB Showing Basic Interconnections G3 G2 BC846BPDW1 162K IN1 IN2 G4 G1 MMBZ27VALT1G BC846BPDW1 G3 If the customer needs to implement a system in which a high voltage 30 V rear auxili...

Страница 5: ... support systems or any FDA Class 3 medical devices or medical devices with a similar or equivalent classification in a foreign jurisdiction or any devices intended for implantation in the human body You agree to indemnify defend and hold harmless onsemi its directors officers employees representatives agents subsidiaries affiliates distributors and assigns against any and all liabilities losses c...

Отзывы: