background image

NB3L208KMNGEVB

www.onsemi.com

2

QUICK START LAB SET-UP USER’S GUIDE

Equipment Required

1. DC Power Supply
2. Oscilloscope
3. Phase Noise Analyzer
4. Connectors for DC Power Supply
5. 50-

W

 SMA Connectors for I/Os

Block Diagram

Figure 2. Time and Frequency Domain Block Diagram

Power Supply

Generator

Tek DPO70404

Agilent E5052B

SSA Signal

Source Analyzer

NB3L208K

CH1 CH2 CH3 CH4

VDD

GND

CLK_IN

CLK_IN

DIF_0−7

DIF_0−7#

Balun

Note: Balun Connected to Outputs Only during Phase Noise Testing.

VDD

GND

DIF_0−7

DIF_0−7#

Power Supplies

Each VDD, VDD_0 (VX on board), GND_0 (DUTGND

on board) and SMAGND power supply has a separate
side-launch banana jack located on bottom side of the test
board (as shown in Figure 1).

HCSL Outputs

HCSL outputs are typically loaded and terminated with

a series resistor (R

SERIES

) = 33-

W

 and 50-

W

 to ground. This

can be easily accomplished by connecting the HCSL outputs
to the 50-

W

 internal impedance in the oscilloscope. There

are on-board R

SERIES

 = 33-

W

 termination resistors installed

for each HCSL output.

Figure 3. Set-Up for HCSL Output

50

W

 to Ground via

SMA Connector to
Oscilloscope

R

SERIES

 = 33

W

Отзывы: