
Setting the Hysteresis
91
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
Setting the Hysteresis
Hysteresis width:
This refers to the difference between the operation point and return point. Set the
hysteresis width for the upper and lower limits of the judgements if the HIGH, PASS or
LOW judgement is unstable near the threshold values.
Procedure for setting up the hysteresis width
1
Set to the MENU mode
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
MENU mode.
Press the button to display
.
* This step is not required if
detail menu display is
already set to ON in the
MENU mode.
Press the button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
HIGH
ON
OFF
ON
OFF
ON
OFF
LOW
PASS
Output
HIGH threshold
Measured value
LOW threshold
Hysteresis (hysteresis width)
Operation point
Return point
Hysteresis width setting
2
Return to RUN mode
3
Set to the MENU mode
1
Setting completed
Hold down for
3 seconds
Lit
Press to display
.
Press to display.
Setting channels used when
connecting multiple units: Each CH