Smart Tuning
80
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
Smart Tuning
Smart tuning:
This setting option sets optimum sensing conditions according to the operating
conditions (response time and color/state of workpiece).
Procedure for setting up smart tuning
• When connecting two or more Amplifier Units and mutual interference prevention is set to
ON, use the CH1 Amplifier Unit to execute tuning. After smart tuning execution for CH1 ends,
it is also executed for the Amplifier Units of CH2 and later.
If the tuning result is NG for either Amplifier Unit, the smart tuning setup results are not
applied to any amplifier units.
1
Set to the MENU mode
2
Response time setting
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
MENU mode.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
* Steps 1, 2 and 4 are not required when the response time
setting is completed since smart tuning can be performed even
in the RUN mode.
Optional setting
Required setting
Response time setting
2
Smart tuning
3
Set to the MENU mode
1
Return to RUN mode
4
Setting completed
Important
Optional
Hold down for
3 seconds
Lit
Optional
Press to display
.
Default value: 500 ms
Setting channels used when connecting multiple units
If mutual interference prevention is ON: CH1
If mutual interference prevention is set to OFF: Each CH