Specifications and Dimensions
140
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
(Note) Highly reflective objects can result in incorrect detection by causing out-of-range measurements.
(*1) Beam size: The beam size is defined by 1/e
2
(13.5%) of the strength of the beam at the beam center
(measured value).
Incorrect detection may occur if there is light leakage outside the defined spot and the material around
the sensing object is more reflective than the sensing object.
(*2) Resolution: The resolution is the deviation (±3
σ
) in the analog output when connected to the ZX2-LDA
Amplifier Unit. (The resolution is measured with the standard reference object (1/4
λ
flat mirror), at the
measurement point when the response time of the ZX2-LDA is set to 128 ms.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the
distance accuracy.
The resolution may be adversely affected under strong electromagnetic fields.
(*3) Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring
the standard reference object.
The linearity and measurement values vary with the object being measured. F.S. is the entire
measurement range.
(*4) Temperature characteristic: The temperature characteristic is measured at the measurement center distance
with the Sensor and reference object (OMRON’s standard reference object) secured with an aluminum jig.
(*5) Categorized as Class 1 by IEC60825-1 criteria in accordance with the stipulations of the FDA standard
Laser Notice No. 50, and registered with CDRH (Center for Devices and Radiological Health) (accession
number: 1020665)
Model
Item
ZX2-LD50V
Optical system Regular-reflective
Light source
(wave length)
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 mW
max.
EN class 1, FDA class 1 (*5)
Measurement
center distance
48 mm
Measurement
range
±5 mm
Beam shape
Spot
Beam size (*1) Approx. 60 µm
Resolution (*2) 1.5 µm
Linearity (*3)
±0.3% F.S. (entire range)
Temperature
characteristic (*4)
0.06% F.S./°C
Ambient
illumination
Incandescent lamp: 10,000 lx max. (on light receiving side)
Ambient
temperature
Operating: 0 to +50°C, Storage: –15 to +70°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute
Vibration
resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes each in X, Y, and Z directions
Shock resistance
(destruction)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Degree of
protection
IEC60529, IP67
Connection
method
Connector connection (standard cable length: 500 mm)
Weight
(packed state)
Approx. 160 g (main unit only: approx. 75 g)
Materials
Case and cover: Polybutylene terephthalate, Optical window: Glass, Screw sections:
Brass, Cable: PVC
Accessories
Instruction sheet, ferrite core
×
1 (made by TDK Corp. ZCAT1730-0730A), laser warning
label (English), FDA certification label