Setting the Differential Function
Differential function:
This function is used to display measurement change amounts when it is difficult to
specify a threshold for the measured value, making it easier to detect only sudden
changes in the measured values.
• The detection effectiveness varies depending on the response time setting.
Procedure for setting up differential function
1
Set to the MENU mode
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
MENU mode.
Setting example:
Making it easier to detect only
sudden changes
Counting gradual changes for which a
threshold value cannot be easily specified.
Input
waveform
Differential
waveform
Differential
waveform
Input
waveform
LOW
HIGH
Shows "0", when detecting no changes.
HIGH output is ON, when the value is over HIGH threshold.
LOW output is ON, when the value is under LOW threshold.
LOW
HIGH
Important
Differential function
setting
2
Return to RUN mode
3
Set to the MENU mode
1
Setting completed
Hold down for
3 seconds
Lit
Setting channels used when connecting multiple units: Each CH