Through-beam Sensor Heads: FUN Mode Functions
Section 3-8
102
3-8-9
Monitor Focus Function
The linear output range and inclination for display values can be specified.
These are set by defining two output values for specified display values.
Refer to
4-5-10 Setting the Monitor Focus
.
When the monitor focus function cannot be set correctly,
refer to
5-2-2 Unable to Set Monitor Focus
.
Examples: Monitor Focus 1
Note:
The zero reset is automatically cleared when the monitor focus is set.
The monitor focus should be set after scaling. It is recommended
that you first confirm the display value for the actual distance (or
width) from scaling, then determine the linear output value that cor-
responds to that display value.
POINT
20
20
20
Linear output
current
(mA)
Linear output current
(mA)
Linear output current
(mA)
4
4
1.25 mm: 4 mA
3.75 mm: 20 mA
0 1.25 3.75 5.0
0 0.625 3.75 5.0
Sensor display value
(mm)
Sensor display value
(mm)
Sensor display value
(mm)
0
5
For these settings:
For these settings:
0.625 mm: 18 mA
3.75 mm: 6 mA
18
6
4
Содержание ZX Series
Страница 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Страница 2: ......
Страница 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Страница 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Страница 160: ...FUN Function Mode Section 4 5 140 Memo ...
Страница 166: ...Setting Problems Section 5 2 146 Memo ...
Страница 185: ...Dimensions Section 6 2 165 6 2 4 Calculating Unit n ZX CAL Connectors Connection indicators Unit mm ...
Страница 186: ...Dimensions Section 6 2 166 Memo ...
Страница 187: ......
Страница 188: ...Z157 E1 01B ...