Setting the Output Conditions
ZW User's Manual
241
Senso
r con
trol
ler ope
ra
ti
ons
9
Automatically Setting Scaling
Performing 1-point Scaling
Performing 1-point Scaling p.84
Operating procedure
Steps
Key operation
Display
Description
1 to 5
For moving to "SCALE", see steps 1 to 5 in p.240.
6
Select "AUTO" as the scaling type.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
Select "AUTO" and press the
key.
7
Select "1POINT".
Press the
/
keys to select "1PT" and press the
key.
8
Press the
key when the main display shows "POINT1".
9
The current measured value is displayed on the main display and the
current setting value is displayed on the sub-display.
To edit numerical values, use the
/
/
/
keys.
Enter the setting value and then press the
key.
10
Set the increment/decrement direction.
"DIRECT" is displayed on the main display and the incremental/
decremental directions ("FWD": the NEAR side as + and "REV": the
FAR side as +) are displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
Enter the setting value and then press the
key.
11
"OK/CAN" is displayed on the sub-display.
Press the
key to execute scaling or
key to cancel.
12
Press the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......